Asbestos TEM analysis, PS 234M, Oct 2001

Machine-extracted title · confidence 42%

TEM asbestos analysis for PS 234M at 292 Greenwich Street, Oct 2001.

NYC-WTC_000324302
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

ATC Environmental, Inc. 104 East 25th Street New York, New York 10010

N.Y.C. Board of Education Approved N.Y. State ELA? #10879 28-11 Queens Plaza North ACCREDITED NVLA? Lab Code # 1187 Long Island City, NY 11101 Report Date: 10/05/01

ASBESTOS FIBER ANALYSIS BY TRANSMISSION ELECTRON MICROSCOPY (TEM) With Fiber Identification by Selected-Area Electron Diffraction (SAED) and Energy-Dispersive ,X-RAY Spectroscopy (EDS) Method: AHERA Final Rule, EPA Federal Register (40 CFR, Part 763), Vol. 52, No. 210, October 30, 1987

Sample IdencifLcation Analysis Parameters

Project/SitaH.S. for Economics & Finance, 100 Trinity Pl., NYC T2M Sample No.: 5606 60125 Entire Building Date Received: 10/04/01 Grid Openings Analysed;__ 4

Project Sample No. : HSSF-S-10/3-47 Average Grid Opening; 106.00 um

Air Volume: 1310 liters Total Area Analysed: 0.0450 mm2

Filter Type; MGS 25 mm diam., Pore Sisa: 0.45 um Analytical Sensitivity:22;2£/mfTi2 Effective Area: 385 mm2 0 ■ 0047 s/cc

FIBROUS PARTICULATES ANALYZED Number Qbsg2rzed CONCENTRATION Total Single Matrix Tocal. Struct. Filter Air Fibers Bundles Clusters Struct. Struct ^•«5utn St2mct/mm2 Struct/cc n.am/m3

Chrysotile Asbestos 0 0 0 0 0 0 0.0 0.0000 0

Amphibole Asbestos 0 0 0 0 0 0 0.0 0.0000 0

Ambiguous 0 0 0 0 0 0 0, 0 0.0000 0

Total asbestos (includes ambiguous structures) 0 0 0.0 G . 0000 0

Non-Asbestos 0 0 0 0 0 0 0.0 0.0000 N/.A Nq Identification 0 0 0 0 0 0 0.0 0.0000 N/A

Totals (All Structures) 0 0 0.0 0.0000 N/A The estimated uncertainty of this analysis is 1 standard deviation.

Non-asbestos fiber i.d. (EDS/SAED): None detected Amphibole Asbestos Type: None detected

The Analysis was carried out in accordance with the approved TEM method. This laboratory is in compliance with the quality specified for the method.

Analyzed by: Report Reviewed by:

Marek Peysakhov Michael A. Gorycki, Ph.D. Director of Electron Microscopy

CITY_21MC100_003267891 NYC-WTC_000324302

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000324302Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000293973

TEM analysis; SAED/EDS; New Stuyvesant HS; received 10/26/01.

Similar indexed content

Compare copies and versions →