ATC Environmental, Inc. 104 East 25th Street New York, New York 10010 N.Y.C. Board of Education Approved N.Y. State ELA? #10879 28-11 Queens Plaza North ACCREDITED NVLAP Lab Code # 1197 Long Island City, NY 11101 Report Date: 10/05/01 ASBESTOS FIBER ANALYSTS BY TRANSMISSION ELECTRON MICROSCOPY (TEM) With Fiber Identification by Selected-Area Electron Diffraction (SAED) and Energy-Dispersive X-RAY Spectroscopy (EDS) Method: AHERA Final Rula, SPA Federal Register (40 CFR, Part 763), Vol. 52, No. 210. October 30, 1987

iampla Identification Analvsis Parameters

?rojecc/sita: H.S. for Economics & Finance, lOQ Trinity PI., NYC TEM Sample No.: 5606 60117 Entire 3uiIdina Date Received; 10/^4/01 Grid Openings Analyzed;__ 4

Project Sample No.: HSEF-E-lQ/3-39 Average Grid Opening

Air Volume .-^iSlOlJx^rs Total Area Analyzed; Q.Q4S0 mm2

Filter Type: MCE 25 mm diam. Pors Size: 0.45 urn Analytical Sensitivity 22.2 s/mm2 Effective Area: 335 mm2 0.0047 s/gg

FIBROUS PARTICULATES ANALYZED Number Observed CONCENTRATION Total Single Matrix Total. Struct. Filter Air Fibers Bundles Ciustars Struct. Struct >=5uni Struct/mm2 Struct/cc ncm/mS

Cbrysotile Asbestos 0 0 0 0 0 0 O.Q 0.0000 0

Amphibole Asbestos 0 0 0 0 0 0 0.0 0.0000 0

Ambiguous 0 0 0 0 0 0 0. 0 0.0000 0

Total asbestos (includes ambiguous structures)- 0 0 0. 0 0.0000 0

Non-Asbestos 0 0 0 0 0 0 0.0 Q.0000 N/A

No Identification 0 0 0 0 0 0 0.0 0.0000 N/A

Totals (Ail Structures) 0 0 O.Q 0 . 0000 N/A The estimated uncertainty of this analysis is 1 standard deviation.

Non-asbestos fiber i.d. (EDS/SAED) : None detected Amphibole Asbestos Type; None detected

The Analysis was carried out in accordance with the approved TEM method. This laboratory is in compliance with the quality specified for the method.

Analyzed by; Report Reviewed by;

Marek Psysakhov Michael A. Gorycki, Ph.D. Director of Eleccron Microscopy

CITY_21MC1OO_OO3267883 NYC-WTC_000324300

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000324300Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →