Asbestos TEM analysis, H.S. for Economics & Finance

Machine-extracted title · confidence 28%

TEM asbestos analysis with SAED/EDS for Economics & Finance site, Oct 2001.

NYC-WTC_000324282
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

ATC Environmental, Inc. 104 East 25th Street New York, New York 10010 N.Y.C. Board of Education Anproved N.Y. State ELA? #10879 23-11 Queens Plaza North ACCREDITED NVLAP Lab Code # 1187 Long Island City, NY 11101 Report Date: 10/05/01 ASBESTOS FIBER ANALYSIS BY TRANSMISSION ELECTRON MICROSCOPY (TEM) Wit-d Fiber Identification by Selected-Area Electron'Diffraction (SAED) and Energy-Dispersive, X-RAY Spectroscopy (EDS) Method: AHERA Final Rule, EPA Federal Register (40 CPR, Part 7S3). 'Vol. S2, No. 210, October 30, 1987

Sample TdenClficabion Analysis Parameters

Project/ Sita: H.5. for Sconomics & Finance, 100 Trinity ?I. , NYC TEM Sample No.: 5606 - 6QQ98 Entire Building Date Received: 10/04/01 Grid Openings Analyzed:' 4

Project Sample No.: HSEF-E-10/3-20 Average Grid Opening: 10 6.0 0 um

Air VoLume: 1820 Liters Total .Area Analyzed: 0.04so mm2

Filter Type: MCS 25 mm diam. Pore Size; 0.45 um Analytical Sensitivity: ’22.2 3/mm2 Effective Area: 385 mm2 .0.0047 s/cc

FIBROUS PARTICULATES ANALYZED Number Ooser'Ysd CONCENTRATION Tocal single Matrix Total. Struct:. Filter Air Fibers Bundles Clusters Struct. Struct >-Sum Struct/mntg Strucc/c; ncrm/m3

Chrysotile Asbestos 0 1 0 0 22.2 0.0047 155

Amphibole Asbestos 0 0 0 0 0 0 0.0 0 . 0000 0

Ambiguous 0 0 0 0 0 0 0.0 0.0000 0

Total asbestos (includes ambiguous structures) 1 22.2 0.004“ 1S5 Non-Asbestos 0 0 0 0 0 0 0.0 0.0000 N/A No Identification 0 0 0 0 0 0 0.0 0,0000 N/A

Totals (All Structures) 1 1 22.2 0.0047 N/A The estimated uncertainty of this analysis is 1 standard deviation.

Non-asbestos fiber i.d. (EDS/SAED) : None detected Amphibole Asbestos Type: None detected The Analysis was carried out in accordance with the approved TEM method. This laboratory is in compliance with the quality specified for the method.

Analyzed by: Report Reviewed by:

Marek Peysakhov Michael A. Gorycki, Fh.D. Director of Electron Microscopy

CITY_21MC100_003267864 NYC-WTC_000324282

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000324282Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000293973

TEM analysis; SAED/EDS; New Stuyvesant HS; received 10/26/01.

Similar indexed content

Compare copies and versions →