Laboratory report of TEM asbestos fiber analysis for samples collected on October 4, 2001.
5 shared non-person entities · 1 shared topics · similarity 0.995
machine-extracted · confidence unavailable · Check page ↗TEM analysis report for HS for Economics & Finance site, Oct 4, 2001.
NYC-WTC_000324274OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
ATC Environmental, Inc. 104 East 25th Street New York, New York 10010
N.Y.C. Board of Education Approved N.Y. State ELA? #10879 23-11 Queens Plaza North ACCREDITED NVLAP Lab Code # 1187 Long Island City, NY 11101 Report Date; 10/05/CT
ASBESTOS FIBER ANALYSIS BY TRANSMISSION ELECTRON MICROSCOPY (TEM) With Fiber Identification by Selected-Area Electron Diffraction (SAED) and Energy'Dispersive X-RAY Spectroscopy (EDS) Method: AHERA Pinal Rule, EPA Federal Register (40 CFR, Part 763), Vol, 52, No, 210. October 30, 1937
Sample Identification Ar.alysis Parameters
Project/Site; H.S. for Eccnomics & Finance, 100 Trinity Pl., NYC TEM Sample No.: 5606 50090 Entire 3uildincr Date Received;_io2O42^ Grid Openings Analysed:__ 4
Project Sample No.: H5SE-S-10/3-12 Average Grid Opening: 106.00 urn
Air Volume: 1810 liters Total Area Analyzed: 0.0450 mm2
Filter Type: MOS 25 mm diam., Pore Size; 0.45 urn Analytical Sensitivity: 22.2 s/mmE Effective Area: 3a5mm2 0 ■ 0047 s/cc
FIBROUS PARTICULATES ANALYZED Number Obser-zed CONCENTRATION Total Single Matrix Total. Struct. Filter Air Fibers Bundles Clusters Struct. Struct > = 5um Str'act/mm2 Struct/cc nam/m3
Chrysotile Asbestos 1 0 0 0 1 1 22.2 0.0047 156
Amphibole, Asbestos 0 0 0 0 0 0 Q-Q 0.0000 0
Ambiguous 0 c 0 0 0 0 0.0 0.0000 Q
Total asbestos (includes ambiguous structures) 1 1 22.2 0.0047 156 Non-Asbestos 0 0 0 c 0 0 0.0 0.0000 N/A No Identification 0 0 •0 0 0 0 0.0 0.0000 N/A
Totals (All Structures) 1 1 22.2 0.0047 N/A The estimaced uncertainty of this analysis is 1 standard deviation.
Non-asbestos fiber i.d. (EDS/SAED): None detected Amphibole Asbestos Type; None detected
The Analysis was carried out in accordance with the approved TEM method. This laboratory is in compliance with the quality specified for the method.
Analyzed by: Report Reviewed by:
Marek Peysakhov Michael A. Gorycki, Ph.D. Director of Electron Microscopy
CITY_21MC100_003267856 NYC-WTC_000324274
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000200243
Laboratory report of TEM asbestos fiber analysis for samples collected on October 4, 2001.
5 shared non-person entities · 1 shared topics · similarity 0.995
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000200240
Laboratory report documenting TEM analysis of air samples collected on October 4, 2001, using AHERA methods.
5 shared non-person entities · 1 shared topics · similarity 0.995
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000324266
TEM analysis report for HS for Economics & Finance project, Oct 4–5, 2001.
5 shared non-person entities · 1 shared topics · similarity 0.995
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000324270
TEM analysis report for HS for Economics & Finance site, Oct 4, 2001.
6 shared non-person entities · 1 shared topics · similarity 0.994
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000293973
TEM analysis; SAED/EDS; New Stuyvesant HS; received 10/26/01.
6 shared non-person entities · 1 shared topics · similarity 0.994
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000270586
TEM asbestos analysis by SAED/EDS for air samples at New Stuyvesant High School.
6 shared non-person entities · 1 shared topics · similarity 0.994
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000205255
Laboratory analysis report for asbestos fibers in air samples collected at the High School for Economics and Finance.
6 shared non-person entities · 1 shared topics · similarity 0.994
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000294135
Asbestos fiber TEM analysis for Stuyvesant HS project; includes SAED/EDS methods.
6 shared non-person entities · 1 shared topics · similarity 0.994
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000248479
TEM asbestos identification and SAED/EDS for Stuyvesant HS, Oct 2001.
5 shared non-person entities · 1 shared topics · similarity 0.994
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000324302
TEM asbestos analysis for PS 234M at 292 Greenwich Street, Oct 2001.
6 shared non-person entities · 1 shared topics · similarity 0.994
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000340278
TEM asbestos analysis for Economics & Finance site, Oct 2001.
6 shared non-person entities · 1 shared topics · similarity 0.994
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000330205
TEM asbestos analysis with SAED/EDS for NYC DOE project, Oct 2001.
7 shared non-person entities · 1 shared topics · similarity 0.994
machine-extracted · confidence unavailable · Check page ↗No available related records indexed in this group.
Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000200243
Laboratory report of TEM asbestos fiber analysis for samples collected on October 4, 2001.
Similarity score 0.998 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000200240
Laboratory report documenting TEM analysis of air samples collected on October 4, 2001, using AHERA methods.
Similarity score 0.997 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000324266
TEM analysis report for HS for Economics & Finance project, Oct 4–5, 2001.
Similarity score 0.997 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000324270
TEM analysis report for HS for Economics & Finance site, Oct 4, 2001.
Similarity score 0.997 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000293973
TEM analysis; SAED/EDS; New Stuyvesant HS; received 10/26/01.
Similarity score 0.997 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000270586
TEM asbestos analysis by SAED/EDS for air samples at New Stuyvesant High School.
Similarity score 0.997 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Machine-extracted building matches; verify each source. Buildings, never households.
Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000200243
Laboratory report of TEM asbestos fiber analysis for samples collected on October 4, 2001.
Similar indexed content
NYC-WTC_000200240
Laboratory report documenting TEM analysis of air samples collected on October 4, 2001, using AHERA methods.
Similar indexed content
NYC-WTC_000324266
TEM analysis report for HS for Economics & Finance project, Oct 4–5, 2001.
Similar indexed content
NYC-WTC_000324270
TEM analysis report for HS for Economics & Finance site, Oct 4, 2001.
Similar indexed content
TEM analysis; SAED/EDS; New Stuyvesant HS; received 10/26/01.
Similar indexed content