NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 8 pages

Ambient air protocol, Stuyvesant HS, 2002

Machine-extracted title · confidence 64%

Ambient air and dust sampling protocol for Stuyvesant High School; asbestos IAQ.

NYC-WTC_000324220–000324227
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

AMBIENT AIR AND DUST SAMPLING PROTOCOL for STUYVESANT H.S. Page 3 of 8

Industrial Hygienists Guide to Indoor Air Quality Investigations (1993), American Industrial Hygiene Association (AIHA).

TARGET GUIDELINES FOR INDOOR AIR QUALITY PARAMETERS EVALUATED

PARAMETE _____ ;_____________ i org;> Temperature (T) Summer 73-79°F at 50% RH ASHRAE 55 Winter. SS-TS^F at 50% RH Relative Humidity (RH) 30-60% ASHRAE 55 Carbon Dioxide (CO2) <700 parts per million (ppm) ASHRAE62 above background level Carbon Monoxide 9 ppm USEPA NPAAQS (as cited in ICOb__________ ASHRAE 62) Total Volatile Organic 1 ppm AIHA Compounds (TVOC) Respirable Particulates 65 micrograms per cubic USEPA NPAAQS (PMxs) meter of air (pg/m^)

USEPA = United States Environmental Protection Agency NPAAQS = National Primary Ambient-Air Quality Standard AIHA = American industrial Hygiene Association ASHRAE = American Society of Heating, Refrigerating, and Air-Conditioning Engineers

Results from samples collected each day shall be reported verbally, no later than Sam the next day, to BOE, UFT, School Principal and the PA consultant. A written report shall be delivered or faxed by the end of the day.

In the event that real-time measurements of Temperature. Relative Humidity, and/or CO2 exceed the cited Target Guidelines, the following actions are to be taken:

- t. Building engineering controfe shall be adjusted and/orimplemented to improve conditions. In the event, that real-time measurements of respirable particulates exceed the cited Target Guidelines, BOE will immediately notify the UFT, the school principal, the school custodian and the PA consultant. The said parties will assess the situation and implement the appropriate response action(s).

In the event, that CO inside the school measured above the cited Target Guidelines (9ppm), BOE will immediately notify the UFT, the school principal, the school custodian and the PA consultant. The said parties will assess the situation and implement the appropriate response action(s).

In the event that real-time measurement(s) of CO inside the school is/are greater than 5ppm and less than 9ppm, BOE will identify the source and assess the situation.

In the event that real-time measurement(s) of TVOC inside the school is/are above the cited Target Guidelines (Ippm), BOE will immediately notify the UFT, the school principal, the

CITy_21MC100_003267281

NYC-WTC_000324222

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000324222Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000385863

Ambient air/dust sampling protocol for Stuyvesant High School following WTC cleanup.

Similar indexed content

Compare copies and versions →