NYC-WTC_000324135
Draft IAQ protocol for asbestos monitoring at BOE schools post-WTC.
15 shared non-person entities · 1 shared topics · similarity 0.982
machine-extracted · confidence unavailable · Check page ↗Ambient air and dust sampling protocol for Stuyvesant High School; asbestos IAQ.
NYC-WTC_000324220–000324227OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document _ .. , -X- 4£^ ______ _ — -------------------- ---------
AMBIENT AIR AND DUST SAMPLING PROTOCOL for STUYVESANT H.S. Page 2 of 8
• South side - 2 samples (one sample from 8am-12pm & one from 12pm-4pm) • 11*^ Floor Roof - 2 samples (one sample from 8am-12pm & one from 12pm-4pm) The duration of all ambient air sample shall be approximately 4 hours. The total air volume sampled at each location shall be approximately 1800 liters.
All ambient air samples collected shall be analyzed via Transmission Electron Microscopy (TEM) in accordance with the methodology of the AHERA Final Rule.
Results from samples collected each day shall be reported verbally, no later than Sam the next day, to BOE, UFT, School Principal and the PA consultant. A written report shall be delivered or faxed by the end of the day. Unsatisfactory results (>70 s/n-m~) shall be reported immediateiy.
In the event that any one sample result exceed 70 s/mm^ BOE will immediately notify the UFT, the school principal, the school custodian and the PA consultant. The said parties will assess the situation and implement the appropriate response action(s).
INDOOR AIR QUALITY
To address lAQ concerns, each day from Monday through Friday, the following shall be performed:
• A visual inspection to assess conditions present in the school at the time of the site visit.
• Collect real-time environmental measurements of temperature (T)
• Collect real-time environmental measurements of relative humidity (RH)
• Collect real-time environmental measurements of carbon dioxide (CO2)
Collect real-time environmental measurements of carbon monoxide (CO)
• Collect real-time environmental measurements of total volatile organic compounds (TVOCs)
• Collect real-time environmental measurements of respirable particulates (PM2.5),
EVALUATION CRITERIA:
Since, there are no regulatory standards for indoor air quality in non-industrial buildings, such as offices and schools at this time, for the real-time data collected, the commonly accepted guidelines cited in the following publications and table below shall be utilized:
Ventilation for Acceptable Indoor Air Quality (ASHRAE 62-1999), American Society of Heating. Refrigerating, and Air-Conditioning Engineers (ASHRAE): Thermal Environmental Conditions for Human Occupancy (ASHRAE 55-1992);
CITY_21MC100_003267280
NYC-WTC_000324221
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000324135
Draft IAQ protocol for asbestos monitoring at BOE schools post-WTC.
15 shared non-person entities · 1 shared topics · similarity 0.982
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000324151
Ambient air protocol for H.S. for Leadership and [name] following WTC cleanup.
16 shared non-person entities · 1 shared topics · similarity 0.981
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000234651
Draft protocol document outlining daily asbestos testing procedures for ambient air at P.S./I.S. 89 Manhattan following the WTC tragedy.
16 shared non-person entities · 1 shared topics · similarity 0.981
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000324195
Ambient air protocol and asbestos IAQ plan for H.S. of Economics & Finance.
16 shared non-person entities · 1 shared topics · similarity 0.981
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000250253
ATC cost estimate letter for environmental services at six schools affected by 9/11.
16 shared non-person entities · 1 shared topics · similarity 0.981
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000385863
Ambient air/dust sampling protocol for Stuyvesant High School following WTC cleanup.
14 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000274908
Draft ambient air/dust sampling protocol for asbestos at Stuyvesant High School.
15 shared non-person entities · 1 shared topics · similarity 0.995
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000385871
Ambient air and dust sampling protocol for High School for Leadership & [name] (M 894).
16 shared non-person entities · 1 shared topics · similarity 0.982
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000236904
Draft protocol for daily ambient air and dust sampling at P.S./I.S. 89 to monitor potential asbestos contamination.
16 shared non-person entities · 1 shared topics · similarity 0.982
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000385905
Draft protocol for ambient air and dust sampling for asbestos at a NYC high school.
16 shared non-person entities · 1 shared topics · similarity 0.981
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000236847
Draft protocol document outlining daily ambient air and dust sampling procedures for PS/IS 89 following the World Trade Center tragedy.
16 shared non-person entities · 1 shared topics · similarity 0.981
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000236871
Draft protocol document outlining daily ambient air and dust sampling procedures for PS/IS 89 following the World Trade Center tragedy.
16 shared non-person entities · 1 shared topics · similarity 0.981
machine-extracted · confidence unavailable · Check page ↗Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000385863
Ambient air/dust sampling protocol for Stuyvesant High School following WTC cleanup.
Similarity score 0.997 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000274908
Draft ambient air/dust sampling protocol for asbestos at Stuyvesant High School.
Similarity score 0.996 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000324135
Draft IAQ protocol for asbestos monitoring at BOE schools post-WTC.
Similarity score 0.986 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000385819
Lab protocol outlining ambient air and dust sampling for asbestos at IS 89 Manhattan.
Similarity score 0.985 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000385808
Protocol detailing daily ambient air sampling inside the IS 89 building.
Similarity score 0.984 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000200230
Draft protocol document establishing daily ambient air and dust sampling procedures for asbestos monitoring at P.S./I.S. 89 Manhattan.
Similarity score 0.984 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
Ambient air/dust sampling protocol for Stuyvesant High School following WTC cleanup.
Similar indexed content
NYC-WTC_000274908
Draft ambient air/dust sampling protocol for asbestos at Stuyvesant High School.
Similar indexed content
NYC-WTC_000324135
Draft IAQ protocol for asbestos monitoring at BOE schools post-WTC.
Similar indexed content
NYC-WTC_000385871
Ambient air and dust sampling protocol for High School for Leadership & [name] (M 894).
Similar indexed content
NYC-WTC_000236904
Draft protocol for daily ambient air and dust sampling at P.S./I.S. 89 to monitor potential asbestos contamination.
Similar indexed content