NYC-WTC_000202619
Laboratory TEM analysis of air samples collected at PS 13QM to detect asbestos fibers using EPA methods.
5 shared non-person entities · 1 shared topics · similarity 0.995
machine-extracted · confidence unavailable · Check page ↗TEM analysis with SAED/EDS for PS 130M; AHERA protocol.
NYC-WTC_000324067OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
ATC Environmental, Inc. 104 East C5th Street New York, New York 10010
K.Y.C. Board of Education Approved N.Y. State ELAP #10879 28-11 Queens Plaza North . ACCREDITED NVLAP Lab Code # 1187 Long Island City, NY 11101 Report Date: 10/19/01
ASBESTOS FIBER ANALYSIS BY TRANSMISSION ELECTRON MICROSCOPY (TEM) With Fiber Identificatio: Selected-Area Electron Diffraction (SAED; and Energy-Dispersive X-RAY- Spectroscopy (EDS) Method; AHERA Final Rule, E?A Federal Register (40 CFR, Part 763), Vol. 52, Ko. 21C, October 30/ 1987
Samnle Identification Analvs-s Pai ante Lers
Project/Site: P.S. ~±4? Baxter St., NY, HY TSM- Sample No.: 5?2c 61666 Throughout the School Building Date Received: 3rio Openings Analyzed:__4
Project Sample No.; ?!*verag£ Grid Opening: 106.00 um
Air Volume: 1855 liters Total Area Analysed; 0,04.60 mmR
Filter Type: MCE 25 mm diam., Pore Size: 0.45 um Analytical Sensitivity: . 22.2 s,^mrr.2 Effective Area: 355 10^2 0.0045 s/cc
FIBROUS PARTICULATES ANALYZED Number Observed CONCENTRATION Total Sin; Matrix Total. Struct. Filter Air Fibers Bundles Clusters Struct. Struct > = 5un; £truct/inm2 Struct/cc ncm/in3
Chrysotile Asbestos c 0 0 0 0 0 0.0 0 0300 0
Amphibole Asbestos 0 0 0 c 0 0 0.0 0.0000 0
Ambiguous c 0 0 0 0 0 0.0 0.0000 0
Total asbestos (includes ambiguous structures) c c 0.0 0.0000 0 Non-Asbestos 0 0 0 0 c c 0.0 0 . 0.000- N/A No Identification 0 0 0 0 C 0.0 0.0000 N/A
Totals (All Structures) c c 0.0 0.0000 KVA The estimated uncertainty o* this analysis is 1 standard deviation.
Non-asbestos fiber i.d. /EDS/SAED): None detected Amphibole -Asbestos Type: None detected
The Analysis was carried out in accordance with the approved TEM method. This laboratory is in compliance with the quality specified for the method.
Analyzed by; Report Reviewed by;
Michael A. Gorycki, Ph.D. Michael . Gorycki, Ph.D. Director of Eleccron Microscopy
CITY_21MC1OO_O11274406
NYC-WTC_000324067
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000202619
Laboratory TEM analysis of air samples collected at PS 13QM to detect asbestos fibers using EPA methods.
5 shared non-person entities · 1 shared topics · similarity 0.995
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000324339
TEM analysis with SAED/EDS for PS 234M, Oct 2001.
6 shared non-person entities · 1 shared topics · similarity 0.994
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000262767
TEM asbestos fiber analysis at PS 234M, includes SAED/EDS methods, Oct 2001.
6 shared non-person entities · 1 shared topics · similarity 0.994
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000329853
TEM asbestos analysis results, PS 130M building-wide.
6 shared non-person entities · 1 shared topics · similarity 0.994
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000329849
TEM asbestos analysis at PS 130M, school building sampling.
6 shared non-person entities · 1 shared topics · similarity 0.994
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000202620
Laboratory TEM analysis of air samples collected at PS 13QM to detect asbestos fibers using EPA methods.
5 shared non-person entities · 1 shared topics · similarity 0.994
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000329864
TEM-based identification of asbestos fibers with SAED/EDS for project site PS 130M/PS 13OM in Oct 2001.
6 shared non-person entities · 1 shared topics · similarity 0.994
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000411527
TEM analysis with SAED/EDS for PS 234M, Oct 2, 2001.
6 shared non-person entities · 1 shared topics · similarity 0.994
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000411526
TEM analysis with SAED/EDS for PS 234M, Oct 2, 2001.
6 shared non-person entities · 1 shared topics · similarity 0.994
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000324075
TEM/SAED/EDS asbestos analysis; AHERA method; PS 130M building.
5 shared non-person entities · 1 shared topics · similarity 0.994
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000411523
TEM analysis with SAED/EDS for PS 234M, Oct 2, 2001.
6 shared non-person entities · 1 shared topics · similarity 0.994
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000411522
TEM analysis with SAED/EDS for PS 234M, Oct 2, 2001.
6 shared non-person entities · 1 shared topics · similarity 0.993
machine-extracted · confidence unavailable · Check page ↗No available related records indexed in this group.
Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000202619
Laboratory TEM analysis of air samples collected at PS 13QM to detect asbestos fibers using EPA methods.
Similarity score 0.997 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000262767
TEM asbestos fiber analysis at PS 234M, includes SAED/EDS methods, Oct 2001.
Similarity score 0.997 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000329853
TEM asbestos analysis results, PS 130M building-wide.
Similarity score 0.997 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000329849
TEM asbestos analysis at PS 130M, school building sampling.
Similarity score 0.997 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000202620
Laboratory TEM analysis of air samples collected at PS 13QM to detect asbestos fibers using EPA methods.
Similarity score 0.997 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000329864
TEM-based identification of asbestos fibers with SAED/EDS for project site PS 130M/PS 13OM in Oct 2001.
Similarity score 0.997 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000202619
Laboratory TEM analysis of air samples collected at PS 13QM to detect asbestos fibers using EPA methods.
Similar indexed content
NYC-WTC_000324339
TEM analysis with SAED/EDS for PS 234M, Oct 2001.
Similar indexed content
NYC-WTC_000262767
TEM asbestos fiber analysis at PS 234M, includes SAED/EDS methods, Oct 2001.
Similar indexed content
NYC-WTC_000329853
TEM asbestos analysis results, PS 130M building-wide.
Similar indexed content
NYC-WTC_000329849
TEM asbestos analysis at PS 130M, school building sampling.
Similar indexed content