NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 1 page

TEM analysis, PS 130M, Oct 16 2001

Machine-extracted title · confidence 45%

TEM analysis of air samples from PS 130M; AHERA method; SAED/EDS.

NYC-WTC_000324062
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

AT Environmental, Inc. 104 East 25th Street New York, New York 10010

N.Y.C. Soard of Education Approved N.Y. State ELAP #10879 28-11 Queens Plaza North ACCREDITED NVLAP Lab Code # 1187 Long Island City, NY 11101 Report Date: 10/19/01

ASBESTOS FIBER -ANALYSIS BY TRANSMISSION ELECTRON MICROSCOPY fTEM) Kith Fiber identification by Selected-Ares Electron Diffraction- (SA2B) and Energ>'-Dispersive X-RAY Spectroscopy (EDS) Method: AKERA Final Ruis, EPA Federal Register (40 CFR. Fart 763), Vol. 52, No. 210, October 30, 1987

Semple Identification Analysis Parametsrs

Prcje; P.S. 130’-:. 143 Ba-ter St,, KY, m.' TEM samcie No.: 5726 €1661 Throughout the School Building Date Received: lU/16i^ Grid Openings Analyzed;__4

Project Sample Ko.: 06 Average Grid Snenincr: 106-00 urn

Air Volume: 1908 liters Total .Area Analyzed: 0.0450 mm2

Filter Tyne; MCE 25 mm di am.' Pore Size: 0.45 um Analytical Sensitivity:___^2,^_2_s2lSmS. Effective ?.rea-. 385 mm2 0.0045 s/ec

FIBROUS PARTICULATES ANALYZED Wvrr.ber Obser\^ed CONCENTRATION Total Single Matrix Total. Strucr, Filter Air Fibers Bundle? Clusters Struct. Struct >r5um Soruct/tnm2 Struct/cc nam/m3

Chrx'sotile A-sbestos 0 C 0 0 0 0 0.0 0.0000 0

Amphibole Asbestos 0 0 0 0 0 G 0.0 O.OODO 0

Ambiguous 0 0 0 0 0 0 C.O 0.0000 0

Total asbestos (includes ambiguous structures) 0 0 0.0 0.0000 0 Non-Asbestos 0 0 0 0 0 0 0.0 0.0000 N/A No Identification 0 0 0 0 U 0 0.0 0-0000 K/A

Totals (All Structures) 0 0 c.c 0.0000 N/A The estimated uncertainty of this analysis is 1 standard deviation.

Non-asbestos fiber i.d. (EDS/SAED): None detected Amphibole Asbestos Type: None detected

The Analysis was carried out in accordance with the approved TEM method. This laboratory is in compliance with the quality specified for the method.

Analyzed by. Report Reviewed by:

Michael A. Gorycki, Ph.D. Michael k. Gorycki, Ph.O. Director of Electron Microscopy

CITY_21MC100_011274401

NYC-WTC_000324062

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000324062Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →