NYC-WTC_000324083
Asbestos TEM analysis with SAED/EDS; project PS 150M, throughout the school building, Oct 1967.
7 shared non-person entities · 1 shared topics · similarity 0.991
machine-extracted · confidence unavailable · Check page ↗Laboratory report detailing asbestos fiber analysis of air samples collected throughout the P.S. 150M school building in October 2001.
NYC-WTC_000200214
OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
ATC Environmental, Inc. 104 East 25th Street New York, New York 10010
N.Y.C. Board of Education Aoproved N.Y. State ELAP #10879 28-11 Queens Plaza North ACCREDITED NVLAP Lab Code # 1187 Long Island City, NY 11101 Report Date: 10/19/01
ASBESTOS FIBER ANALYSIS BY TRANSMISSION ELECTRON MICROSCOPY (TEM) Kith Fiber Identification by Selectec-Arsa Electron Diffraction (.5AED, ar-d Energy-Dispersive X-RA.y Spectroscopy (EDS) Method: AH2RA Final Fule, EPA Federal /Register (40 CFR, Part 763), Vol. 52, No, 21C, October 30, 1967
Sample Identification Analysts Parameters
Project/Site: P.S. 150M, 143 Baxter St.. NY, KY TEM Sample No.: 5726 Throughout the School Building Date Received:^2O/2EV£1 Grid Openings Analyzed;__4
Project Sample No.: 05 Average Grid Opening; I06.QC nm
Air Vclume; 1908 liters Total Area Analyzed; 0.0450 rnni2
Filter Tinoe: MCE 25 mm diam. Site: 0.45 uin Analytical Sensitivity Effective Area-. 585 n-2 C .004.5 s/cc
FIBROUS PARTICULATES ANALYZED .Nuntber Observed CONCENTRATION Total Single Matrix Total. Struct. Filter Air Fibers Bundles Clusters Struct. .Struct >-Sum Struct/Tnm2 Struct/cc nam/n5
Chrysotile .Asbestos 0 C D 0 C 0 0.0 0.0000 0
Amphibole Asbestos 0 0 0 0 C 0 C.0 0.0000 0
Ambiguous 0 0 0 0 0 0 c.o 0.0000 0
Total asbestos (includes ambiguous structures} 0 0 c.o 0.0000 0 Non-Asbestos 0 0 0 0 C 0 0.0 0.0000 N/A No Identification 0 0 0 0 0 c 0.0 0.0000 N/A
Totals (All Structures) 0 c o.c 0.0000 N/A The estimiatec uncertainty of this analysis is 1 standard deviation.
Non-asbestos fiber i.d. (EDS/SAED); None detected Amphibole Asbestos Type: None detecred
The Analysis was carried out in accordance with the approved TEM method. This laboratory is in compliance with the quality specified for the method.
Analyzed by: Report Reviewed by:
Michael A. Gorycki, Ph.D. Michael .A. Gorycki, nh. n. Director of Electron Microscopy
CITY_21MC100_011274400
NYC-WTC_000200214
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000324083
Asbestos TEM analysis with SAED/EDS; project PS 150M, throughout the school building, Oct 1967.
7 shared non-person entities · 1 shared topics · similarity 0.991
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000262768
TEM asbestos analysis for PS 234M; SAED/EDS identification, Oct 2001.
6 shared non-person entities · 1 shared topics · similarity 0.991
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000324339
TEM analysis with SAED/EDS for PS 234M, Oct 2001.
6 shared non-person entities · 1 shared topics · similarity 0.991
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000329863
TEM asbestos fiber analysis performed across the school building on 10/16/01 for P.S. 130M.
7 shared non-person entities · 1 shared topics · similarity 0.991
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000262773
TEM asbestos analysis at PS 234M; SAED/EDS identification, Oct 2001.
6 shared non-person entities · 1 shared topics · similarity 0.990
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000329849
TEM asbestos analysis at PS 130M, school building sampling.
7 shared non-person entities · 1 shared topics · similarity 0.990
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000329852
TEM asbestos analysis results for PS 130M site.
6 shared non-person entities · 1 shared topics · similarity 0.990
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000202620
Laboratory TEM analysis of air samples collected at PS 13QM to detect asbestos fibers using EPA methods.
8 shared non-person entities · 1 shared topics · similarity 0.990
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000411527
TEM analysis with SAED/EDS for PS 234M, Oct 2, 2001.
5 shared non-person entities · 1 shared topics · similarity 0.990
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000329853
TEM asbestos analysis results, PS 130M building-wide.
7 shared non-person entities · 1 shared topics · similarity 0.990
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000329867
TEM asbestos analysis; SAED/EDS identification; project/site PS 130M, throughout building; 10/19/01.
4 shared non-person entities · 1 shared topics · similarity 0.990
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000202619
Laboratory TEM analysis of air samples collected at PS 13QM to detect asbestos fibers using EPA methods.
8 shared non-person entities · 1 shared topics · similarity 0.990
machine-extracted · confidence unavailable · Check page ↗No available related records indexed in this group.
Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000324083
Asbestos TEM analysis with SAED/EDS; project PS 150M, throughout the school building, Oct 1967.
Similarity score 0.996 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000262768
TEM asbestos analysis for PS 234M; SAED/EDS identification, Oct 2001.
Similarity score 0.996 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000329863
TEM asbestos fiber analysis performed across the school building on 10/16/01 for P.S. 130M.
Similarity score 0.995 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000262773
TEM asbestos analysis at PS 234M; SAED/EDS identification, Oct 2001.
Similarity score 0.995 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000329849
TEM asbestos analysis at PS 130M, school building sampling.
Similarity score 0.995 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000329852
TEM asbestos analysis results for PS 130M site.
Similarity score 0.995 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000324083
Asbestos TEM analysis with SAED/EDS; project PS 150M, throughout the school building, Oct 1967.
Similar indexed content
NYC-WTC_000262768
TEM asbestos analysis for PS 234M; SAED/EDS identification, Oct 2001.
Similar indexed content
NYC-WTC_000324339
TEM analysis with SAED/EDS for PS 234M, Oct 2001.
Similar indexed content
NYC-WTC_000329863
TEM asbestos fiber analysis performed across the school building on 10/16/01 for P.S. 130M.
Similar indexed content
NYC-WTC_000262773
TEM asbestos analysis at PS 234M; SAED/EDS identification, Oct 2001.
Similar indexed content