ATC Environmental, Inc. 104 East 25th Street New York, New York 10010

NYC School Construction Authority Approved N.Y. State ELAP #10879 30-30 Thomson Avenue ACCREDITED NVLAP Lab Code # 1137 Long Island City, NY 11101 Report Date: 09/17/01

ASBESTOS FIBER ANALYSIS BY TRANSMISSION ELECTRON MICROSCOPY (TEM) With Fiber Identification by Selected-Area Electron Diffraction (SAED) and Energy-Dispersive X-RAY Spectroscopy (EDS) Method: AHERA Final Rule, EPA Federal Register (40 CFR, Part 763), Vol. No. 210, October 30, 1987

Sample Identification Analysis Parameters

Project/Site; World Trade -enter, NY, NY TEM Sample No.: 5515 59046 Personal Mo.uitcring Date Received; 09/17/01 Grid Openings Analyzed: 10

Project Sample No.: 030 Average Grid Opening: 106.OQ um

Air Volume; 60 liters Total Area Analyzed: 0.1124 mm2

Filter Type: MCE 25 mm diam., Pore Size; 0.45 urn Analytical Sensitivity:8^;9 s/nTm2 Effective Area: 385 mm2 0.0571 s/cc

FIBROUS PARTICULATES ANALYZED Number Observed CONCENTRATION Total Single Matrix Total. Struct. Filter Air Fibers Bundles Clusters Struct. Struct > = 5um Struct/mni2 Struct/cc nam/m3

Chrysotile Asbestos 0 0 0 2 2 0 17.8 0.1142 3768

Amphibole Asbestos 0 0 0 0 0 0 0.0 0.0000 0

Ambiguous 0 0 0 0 0 0 0.0 0.0000 0

Total asbestos (includes ambiguous structures) 2 0 17.8 0.1142 3768 Non-Asbestos 0 0 0 0 0 0 0.0' 0.0000 N/A NO Identification 0 0 0 0 0 0 0.0 0.0000 N/A

Totals (All Structures) 2 0 17.8 0.1142 N/A The estimated uncertainty of this analysis is 1 standard deviation.

Non-asbestos fiber i.d. (EDS/SAED): None detected Amphibole Asbestos Type: None detected

The Analysis was carried out in accordance with the approved TEM method. This laboratory is in compliance with the quality specified for the method.

Analyzed by: Report Reviewed by:

Roman Peysakhov Michael A. Gorycki, Ph.D. Director of Electron Microscopy

CITY_21MC100_003265520

NYC-WTC_000322886

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000322886Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →