Liberty Mutual. ^-pQ industrial hygiene ASBESTOS TEM RESULTS

Asbestos Air Sample Information Sheet

The air samples being collected at the World Trade Center site by ATC, Inc. under the direction of Liberty Mutual are analyzed using two independent analytical methods as described below.

Phase-Contrast Microscopy (PCM) Analysis All asbestos samples collected by ATC for the purposes of worker exposure assessment are analyzed by the PCM method. This is a fiber counting method in which fibers are counted under an optical microscope. This is the method used to compare results to the OSHA Permissible Exposure Limit (PEL) and to the Threshold Limit Value (TLV) for asbestos. This method is quick and inexpensive and is the standard method used for measuring worker exposure. One limitation of the PCM method is that it cannot reliably distinguish between asbestos fibers and other types of fibers, such as mineral wool, glass fibers, etc. So, any asbestos air sample showing fiber counts in excess of 50% of the shift-adjusted occupational exposure limit (OEL) is also sent away for transmission electron microscopy analysis.

Transmission Electron Microscopy (TEM) Those air samples showing fiber counts in excess of 50% of the shift adjusted OEL by PCM analysis are also analyzed using TEM analysis. This can be done on the very same filter that was analyzed by PCM because only a portion of the filter is used for each analysis. TEM analysis provides information on the structure of fibers, so the TEM method can distinguish between asbestos and other types of fibers. TEM analysis is more time-consuming and expensive than PCM analysis and these are two of the reasons why TEM analysis is not used as a standard method for measuring worker exposure. Since it is not a standard method, there are no occupational exposure limits to which to compare TEM results. Although TEM analysis can provide information on fiber counts, in the occupational setting, TEM analysis is primarily used to identify the types of fibers collected on a sample.

Air Sample Results The attached information contains results of both PCM and TEM analyses. For each sample, the upper line contains the PCM results. The PCM results have been reported earlier as part of the “elevated exposure” reporting process. The lower line for each sample contains the results of the TEM analysis. If asbestos was found by TEM, the asbestos fiber count is reported.

If you have questions about this information, please call the Liberty Mutual industrial hygienist on duty at 917-566-2576.

3/21/2002 2

CITY_21MC100_011187495

NYC-WTC_000322662

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000322662Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

No available related records indexed in this group.

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

WTC Building asbestos TEM results, 2002

NYC-WTC_000454208

TEM asbestos results for three air samples from Banker's Building related to WTC site, indicating low chrysotile presence.

Similar indexed content

Compare copies and versions →