NYC-WTC_000280577
Air sampling data for WTC site with OELs and percent of OEL values listed.
4 shared non-person entities · 1 shared topics · similarity 0.991
machine-extracted · confidence unavailable · Check page ↗Describes PCM and TEM methods for asbestos air sample analysis at WTC site.
NYC-WTC_000322662
OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
Liberty Mutual. ^-pQ industrial hygiene ASBESTOS TEM RESULTS
Asbestos Air Sample Information Sheet
The air samples being collected at the World Trade Center site by ATC, Inc. under the direction of Liberty Mutual are analyzed using two independent analytical methods as described below.
Phase-Contrast Microscopy (PCM) Analysis All asbestos samples collected by ATC for the purposes of worker exposure assessment are analyzed by the PCM method. This is a fiber counting method in which fibers are counted under an optical microscope. This is the method used to compare results to the OSHA Permissible Exposure Limit (PEL) and to the Threshold Limit Value (TLV) for asbestos. This method is quick and inexpensive and is the standard method used for measuring worker exposure. One limitation of the PCM method is that it cannot reliably distinguish between asbestos fibers and other types of fibers, such as mineral wool, glass fibers, etc. So, any asbestos air sample showing fiber counts in excess of 50% of the shift-adjusted occupational exposure limit (OEL) is also sent away for transmission electron microscopy analysis.
Transmission Electron Microscopy (TEM) Those air samples showing fiber counts in excess of 50% of the shift adjusted OEL by PCM analysis are also analyzed using TEM analysis. This can be done on the very same filter that was analyzed by PCM because only a portion of the filter is used for each analysis. TEM analysis provides information on the structure of fibers, so the TEM method can distinguish between asbestos and other types of fibers. TEM analysis is more time-consuming and expensive than PCM analysis and these are two of the reasons why TEM analysis is not used as a standard method for measuring worker exposure. Since it is not a standard method, there are no occupational exposure limits to which to compare TEM results. Although TEM analysis can provide information on fiber counts, in the occupational setting, TEM analysis is primarily used to identify the types of fibers collected on a sample.
Air Sample Results The attached information contains results of both PCM and TEM analyses. For each sample, the upper line contains the PCM results. The PCM results have been reported earlier as part of the “elevated exposure” reporting process. The lower line for each sample contains the results of the TEM analysis. If asbestos was found by TEM, the asbestos fiber count is reported.
If you have questions about this information, please call the Liberty Mutual industrial hygienist on duty at 917-566-2576.
3/21/2002 2
CITY_21MC100_011187495
NYC-WTC_000322662
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
No available related records indexed in this group.
NYC-WTC_000280577
Air sampling data for WTC site with OELs and percent of OEL values listed.
4 shared non-person entities · 1 shared topics · similarity 0.991
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000208744
Lab report detailing industrial hygiene asbestos air sample analysis methods including PCM and TEM for worker exposure assessment.
4 shared non-person entities · 1 shared topics · similarity 0.988
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000454208
TEM asbestos results for three air samples from Banker's Building related to WTC site, indicating low chrysotile presence.
4 shared non-person entities · 1 shared topics · similarity 0.972
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000338506
Comparison of PCM and TEM methodologies for asbestos exposure assessment.
1 shared non-person entities · 1 shared topics · similarity 0.934
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000338508
Overview of asbestos monitoring results and TEM/PCM interpretation for ERA data.
1 shared non-person entities · 1 shared topics · similarity 0.932
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000242845
Air tests at four indoor/outdoor locations; asbestos/fibers assessed in air and dust.
1 shared non-person entities · 1 shared topics · similarity 0.927
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000242804
Summary of asbestos air and dust results for Park Place building; multiple sample locations.
1 shared non-person entities · 1 shared topics · similarity 0.926
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000242217
DOHMH lab report summarizing asbestos air test results at 55 Liberty Street residences and hallway.
1 shared non-person entities · 1 shared topics · similarity 0.925
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000353880
Asbestos dust samples from 366 [name]; TEM/PLM analysis indicates very low asbestos content.
1 shared non-person entities · 1 shared topics · similarity 0.925
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000320150
Ames dust samples and TEM/PLM results showing asbestos content below detectable levels in most samples.
1 shared non-person entities · 1 shared topics · similarity 0.925
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000338359
DOHMH asbestos air sampling at 450 [name] Ave; results below indoor air standards.
1 shared non-person entities · 1 shared topics · similarity 0.925
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000242876
Four locations tested; air samples collected; results document asbestos and other fibers in dust.
1 shared non-person entities · 1 shared topics · similarity 0.924
machine-extracted · confidence unavailable · Check page ↗Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000454208
TEM asbestos results for three air samples from Banker's Building related to WTC site, indicating low chrysotile presence.
Similarity score 0.998 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000280577
Air sampling data for WTC site with OELs and percent of OEL values listed.
Similarity score 0.995 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000208744
Lab report detailing industrial hygiene asbestos air sample analysis methods including PCM and TEM for worker exposure assessment.
Similarity score 0.994 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000338506
Comparison of PCM and TEM methodologies for asbestos exposure assessment.
Similarity score 0.967 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000241781
Draft confidential sampling and exposure monitoring plan for WTC debris events.
Similarity score 0.967 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000338508
Overview of asbestos monitoring results and TEM/PCM interpretation for ERA data.
Similarity score 0.966 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000280577
Air sampling data for WTC site with OELs and percent of OEL values listed.
Similar indexed content
NYC-WTC_000208744
Lab report detailing industrial hygiene asbestos air sample analysis methods including PCM and TEM for worker exposure assessment.
Similar indexed content
NYC-WTC_000454208
TEM asbestos results for three air samples from Banker's Building related to WTC site, indicating low chrysotile presence.
Similar indexed content
NYC-WTC_000338506
Comparison of PCM and TEM methodologies for asbestos exposure assessment.
Similar indexed content
NYC-WTC_000338508
Overview of asbestos monitoring results and TEM/PCM interpretation for ERA data.
Similar indexed content