NYC-WTC_000357663
TEM asbestos results for three samples from Banker’s Building; two below detection, one ~1% chrysotile.
3 shared non-person entities · 1 shared topics · similarity 0.964
machine-extracted · confidence unavailable · Check page ↗TEM asbestos results for three air samples from Banker's Building related to WTC site, indicating low chrysotile presence.
NYC-WTC_000454208–000454209
OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
Liberty INDUSTRIAL HYGIENE ASBESTOS TEM RESULTS
Asbestos Air Sample Information Sheet
The air samples being collected at the World Trade Center site by ATC, Inc. under the direction of Liberty Mutual are analyzed using two independent analytical methods as described below.
Phase-Contrast Microscopy (PCM) Analysis All asbestos samples collected by ATC for the purposes of worker exposure assessment are analyzed by the PCM method. This is a fiber counting method in which fibers are counted under an optical microscope. This is the method used to compare results to the OSHA Permissible Exposure Limit (PEL) and to the Threshold Limit Value (TLV) for asbestos. This method is quick and inexpensive and is the standard method used for measuring worker exposure. One limitation of the PCM method is that it cannot reliably distinguish between asbestos fibers and other types of fibers, such as mineral wool, glass fibers, etc. So, any asbestos air sample showing fiber counts in excess of 50% of the shift-adjusted occupational exposure limit (OEL) is also sent away for transmission electron microscopy analysis.
Transmission Electron Microscopy (TEM) Those air samples showing fiber counts in excess of 50% of the shift adjusted OEL by PCM analysis are also analyzed using TEM analysis. This can be done on the very same filter that was analyzed by PCM because only a portion of the filter is used for each analysis. TEM analysis provides information on the structure of fibers, so the TEM method can distinguish between asbestos and other types of fibers. TEM analysis is more time-consuming and expensive than PCM analysis and these are two of the reasons why TEM analysis is not used as a standard method for measuring worker exposure. Since it is not a standard method, there are no occupational exposure limits to which to compare TEM results. Although TEM analysis can provide information on fiber counts, in the occupational setting, TEM analysis is primarily used to identify the types of fibers collected on a sample.
Air Sample Results The attached information contains results of both PCM and TEM analyses. For each sample, the upper line contains the PCM results. The PCM results have been reported earlier as part of the “elevated exposure” reporting process. The lower line for each sample contains the results of the TEM analysis. If asbestos was found by TEM, the asbestos fiber count is reported.
If you have questions about this information, please call the Liberty Mutual industrial hygienist on duty at 917-566-2576.
2 3/21/2002
CITY_21MC100_0 02779505
NYC-WTC_000454209
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000357663
TEM asbestos results for three samples from Banker’s Building; two below detection, one ~1% chrysotile.
3 shared non-person entities · 1 shared topics · similarity 0.964
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000280577
Air sampling data for WTC site with OELs and percent of OEL values listed.
4 shared non-person entities · 1 shared topics · similarity 0.962
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000208744
Lab report detailing industrial hygiene asbestos air sample analysis methods including PCM and TEM for worker exposure assessment.
4 shared non-person entities · 1 shared topics · similarity 0.961
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000280576
Chain of custody for air monitoring data collected at WTC site.
3 shared non-person entities · 1 shared topics · similarity 0.960
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000322662
Describes PCM and TEM methods for asbestos air sample analysis at WTC site.
4 shared non-person entities · 1 shared topics · similarity 0.972
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000322661
TEM asbestos results for air samples at World Trade Center site; 3 samples.
3 shared non-person entities · 1 shared topics · similarity 0.959
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000242217
DOHMH lab report summarizing asbestos air test results at 55 Liberty Street residences and hallway.
1 shared non-person entities · 1 shared topics · similarity 0.943
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000242845
Air tests at four indoor/outdoor locations; asbestos/fibers assessed in air and dust.
1 shared non-person entities · 1 shared topics · similarity 0.942
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000242855
Summary of asbestos air/dust sampling results at 55 Liberty Street.
1 shared non-person entities · 1 shared topics · similarity 0.940
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000367211
Summary of asbestos air testing results; November 14, 2001 sampling in building and residences.
1 shared non-person entities · 1 shared topics · similarity 0.940
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000199612
A lab report summarizing asbestos air and dust sampling results from five locations at a building on November 14, 2001.
1 shared non-person entities · 1 shared topics · similarity 0.940
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000275398
Summary of asbestos air testing results for duplicate page entry at 55 Liberty Street.
1 shared non-person entities · 1 shared topics · similarity 0.940
machine-extracted · confidence unavailable · Check page ↗Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000280577
Air sampling data for WTC site with OELs and percent of OEL values listed.
Similarity score 0.998 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000322662
Describes PCM and TEM methods for asbestos air sample analysis at WTC site.
Similarity score 0.998 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000208744
Lab report detailing industrial hygiene asbestos air sample analysis methods including PCM and TEM for worker exposure assessment.
Similarity score 0.997 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000338506
Comparison of PCM and TEM methodologies for asbestos exposure assessment.
Similarity score 0.971 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000338508
Overview of asbestos monitoring results and TEM/PCM interpretation for ERA data.
Similarity score 0.970 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000241781
Draft confidential sampling and exposure monitoring plan for WTC debris events.
Similarity score 0.970 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000322662
Describes PCM and TEM methods for asbestos air sample analysis at WTC site.
Similar indexed content
NYC-WTC_000357663
TEM asbestos results for three samples from Banker’s Building; two below detection, one ~1% chrysotile.
Similar indexed content
NYC-WTC_000280577
Air sampling data for WTC site with OELs and percent of OEL values listed.
Similar indexed content
NYC-WTC_000208744
Lab report detailing industrial hygiene asbestos air sample analysis methods including PCM and TEM for worker exposure assessment.
Similar indexed content
NYC-WTC_000280576
Chain of custody for air monitoring data collected at WTC site.
Similar indexed content