5.01 Asbestos Before BOE DSF EHS and the SCA conducted any cleanup activities at the schools, air, bulk and dust wipe samples were taken in a number of locations by a third party environmental firm ATC Associates. The samples were analyzed for asbestos. The representative air samples were analyzed by Transmission Electron Microscopy (TEM, the most sensitive analytical method) for asbestos. All samples were well below the 70 asbestos structures per square millimeter regulatory requirement mandated by the US Environmental Protection Agency (EPA) under the Asbestos Hazard Emergency Response Act (AHERA) standard for allowing children to re-enter school buildings after asbestos removal activities.

Representative bulk samples of debris were collected inside and outside each school building. None of the bulk samples tested positive for asbestos. A bulk sample is considered positive if it contains greater than 1% asbestos material. Representative settled dust wipe samples were taken inside and outside the building prior to the cleaning of the schools (including in the mechanical equipment rooms and an outside air intake). No asbestos was detected in any of the representative wipe samples. The wipe sample tests are qualitative tests and indicate the presence or absence of asbestos, but do not quantify the amounts..

Therefore, prior to any cleanup activity in the school, the air monitoring results indicated the schools met local, state and federal asbestos regulatory criteria for re-occupancy.*

5.02 Other Environmental Monitoring

ATC Associates also conducted extensive monitoring for a number of contaminants: fiberglass, volatile organic compounds (VOC’s) including benzene, metals including lead and mercury, polychlorinated biphenyls, dioxins, and hydrogen cyanide. Direct reading measurements for respirable particulates, carbon monoxide, sulfur dioxide, hydrogen sulfide, nitrogen oxide, nitrogen dioxides, and VOC’s were also done. Monitoring was conducted prior to and after the cleaning of the building as well as with the mechanical ventilation system on and off. Any environmental contaminants detected were negligible (i.e., below a public health concern). All monitoring results demonstrate the school is safe for re-occupancy.

5.03 Cleaning of the School - Program for PS/IS 89 Between December 2001 and January 7, 2002, the SCA cleaned all the rooms, corridors and floors in the school to remove all visible dust and particulates. Hard surfaces were wet-cleaned and then vacuumed with a high-efficiency particulate air (HEPA) vacuum. HEPA vacuums have filters designed to remove microscopic particles including dust and debris from the area. Furniture and items found in the school (i.e..

‘Follow-up test data at H.S. of Economics and Finance indicated traces of asbestos in the hung ceiling areas that required a complete re-cleaning before occupancy. A:VB_netromtkngHVAC_R.Cascone.doc

Page 7 CITY_21MC100_009093086

NYC-WTC_000322252

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000322252Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →