1.0 SCOPE AND APPLICATION

The purpose of this Standard Operating Procedure (SOP) is to define the procedures for collection of carpet- embedded dust samples that can then be analyzed for lead, pesticides, or other chemical compounds and elements. This procedure is applicable for the collection of samples on a variety of surfaces.

These are standard (i.e., typically applicable) operating procedures which may be varied or changed as required, dependent upon site conditions, equipment limitations or limitations imposed by the procedure. In all instances, the ultimate procedures employed should be documented and associated with the final report.

Mention of trade names or commercial products does not constitute U.S. Environmental Protection Agency (U.S. EPA) endorsement or recommendation for use.

2.0 METHOD SUMMARY

Sample collection is performed utilizing the Nilfisk GS-80 vacuum cleaner equipped with a high efficiency particulate air (HEPA) filter. A diagram of the Nilfisk GS-80 vacuum cleaner is presented in Eigure 1. Soil and other particulate matter with aerodynamic diameters of approximately 5-micrometers (um) and larger, embedded within the carpet, are collected and returned to the laboratory for sieving and analysis.

3.0 SAMPLE PRESERVATION, CONTAINERS, HANDLING AND STORAGE

Eollowing collection of the sample into a dedicated collection bag, the bag is removed from the vacuum cleaner and placed into a 32-ounce glass jar. Storage of the samples at ambient temperature is appropriate for samples that will be analyzed only for metals.

Note: Samples for organic analysis should be maintained at approximately 4°C.

4.0 INTEREERENCES AND POTENTIAL PROBLEMS

There are no known interferences with this method.

5.0 EQUIPMENT/APPARATUS

5.1 Equipment List

-Nilfisk Model GS-80 vacuum cleaner -Two meter folding ruler or similar device ■Masking tape ■Clean aluminum foil ■Shaker sieve, as specified in ASTM D4222, with TOQ^mesh screen ■Analytical balance [sensitive to a minimum 0.1 milligram (mg) and weighing range of 0.1 mg- 1000 grams (g)]. ■Distilled water ■Methanol ■Kimwipes or other laboratory tissue ■Vacuum collection bags ■Polyliners -32-ourice glass jars

1

CITy_21MC100_004068069

NYC-WTC_000321810

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000321810Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →