NYC 9/11 Public Portal Document
wtc settled dust—8,9,11.17,20,21,23, 30 attach 2
Buildings with ND fibrous glass indoor, no sample outdoors
Results of Settled Dust Sampling in Building 8
(99 Battery Place)
On November 18, 2001, settled dust samples were collected from inside 2 residential
units and from 1 common area. Because there was no visible dust present, no outdoor
sample was collected. The dust was analyzed for fibers such as asbestos and fiberglass,
and for silica (quartz) and other minerals. The results of the settled dust samples are the
focus of this attachment. Air sample results collected at these same locations will be
provided as soon as they are received from the laboratory and evaluated.
Settled dust samples were collected from indoor floors by using a specialized vacuum
cleaner. At the laboratory, samples were analyzed for fibrous glass using Polarized Light
Microscopy (PLM). PLM can distinguish fibrous glass from fibers like asbestos by the
appearance and the distinguishing color given off by each different type of fiber. X-Ray
Diffraction (XRD) was used to analyze the samples for all of the mineral analytes
(quartz, cristobalite, tridymite, calcite, port/lime, gypsum, mica, and halite). XRD
analysis identifies crystalline materials by their unique fingerprint given off (a diffraction
pattern) from a beam of X-Ray.
The results of your building along with the results of the indoor samples collected in
comparison residential buildings above 59*** Street are displayed in the table. No dust was
available to collect in comparison building outdoor locations. Results of mineral
analytes are comparable to those found inside homes above 59* Street. Fibrous glass was
not detected in any of the dust samples collected inside your building.
Fibrous
Building Quartz Cristobalite Tridymite Calcite Port/Lime Gypsum Mica Halite Glass
Number Sample site [%] [%1 [%] [%] [%1 [%] [%] [%1 [%]
Common Area
8 (Lobby) 18.5 ND ND 9.4 2.2 14.5 ND ND ND
8 Outdoor NS NS NS NS NS NS NS NS NS
8 Residence 1 14.7 ND ND 10 3.4 16.7 ND ND ND
8 Residence 2 28.1 ND ND 21.4 3.9 6.2 ND ND ND
Comparison Indoors ND-2.2 ND ND ND-0.9 ND-0.08 ND-4.2 ND-0.08 ND-0.4 ND
Buildings Outdoor NS NS NS NS NS NS NS NS NS
ND = not detected
NS = not sampled (not enough visible dust to sample)
CITY_21MC100_003051736
NYC-WTC_000321584