Dust sampling results, 400 [name] Ave, 2001

Machine-extracted title · confidence 41%

Building 15: settled dust sampling; PLM/XRD analyses described; results pending.

NYC-WTC_000321601
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Buildings with <5 fibrous glass indoor, >5 outdoors outdoors

Results of Settled Dust Sampling in Building 15 (400 North End Avenue)

On November 23, 2001, settled dust samples were collected from inside 2 residential units, 1 common area, and from 1 outdoor area close to your building. The dust was analyzed for fibers such as asbestos and fiberglass, and for silica (quartz) and other minerals. The results of the settled dust samples are the focus of this attachment. Air sample results collected at these same locations will be provided as soon as they are received from the laboratory and evaluated.

Settled dust samples were collected from indoor floors by using a specialized vacuum cleaner. The outdoor sample was collected by scraping visible settled material into a container. At the laboratory, samples were analyzed for fibrous glass using Polarized Light Microscopy (PLM). PLM can distinguish fibrous glass from fibers like asbestos by the appearance and the distinguishing color given off by each different type of fiber. X- Ray Diffraction (XRD) was used to analyze the samples for all of the mineral analytes (quartz, cristobalite, tridymite, calcite, port/lime, gypsum, mica, and halite). XRD analysis identifies crystalline materials by their unique fingerprint given off (a diffraction pattern) from a beam of X-Ray.

The results of your building along with the results of the indoor samples collected in comparison residential buildings above 59“* Street arc displayed in the table. No dust was available to collect in comparison building outdoor locations. Results of mineral analytes are comparable to those found inside homes above 59* Street. Indoor dust levels of 5% fibrous glass were found; none was detected in the comparison homes. 72% fibrous glass was detected in the outdoor sample.

Fibrous Building Quartz Cristobalite Tridymite Calcite Port/Lime Gypsum Mica Halite Glass Number Sample site [%] [%] [%] [%1 [%] [%] [%] 1%] 15 Common Area 0.4 ND ND 0.02 ND 1.2 ND ND ND 15 Outdoor 1.1 ND ND ND 0.3 2.1 ND ND 72 15 Residence 1 ND ND ND ND ND 1.1 ND ND ND 15 Residence 2 ND ND ND ND ND ND ND ND 5

Comparison Indoor ND-2.2 ND ND ND-0.9 ND-0.08 ND-4.2 ND-0.08 ND-0.4 ND Buildings Outdoor NS NS NS NS NS NS NS NS NS ND = not detected NS = not sampled (not enough visible dust to sample)

CITY_21MC100_003051755

NYC-WTC_000321601

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000321601Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →