Air sampling locations, Oct 2001

Machine-extracted title · confidence 41%

NYC/ER and NJ/ER asbestos monitoring; some locations not sampled due to pump/malfunction; one exceedance at indoor wash location.

NYC-WTC_000321276–000321280
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

NYC/ER (Oct 15)-PCBs o Trace amounts detected in 1 of 10 samples. o 9 samples did not detect any PCBs. o All concentrations are below the EPA R emoval Action level guidelines.

NYC / ER (Oct 15) - Silicates o All 10 samples either did not detect any silicates or were below the NIOSH Recommended Exposure Limit (REL) TWA of 0.05 mg/m’.

NYC / ER (Oct 28) - Particulate Monitoring (I’M, 5) o Pace University (Site 1) - 24-hr average concentration for this period was 5.82 ug/m\ o Manhattan Boro Community College (Site 2) - 24-hour average concentration for this period was 6.49 ug/tn. o Coast Guard Building - Battery Park (Site 3) - 24-hour average concentrations for this period was 5.96 ug/m^. o All readings below the National Ambient Air Quality Standard for PM2 5 (65 ug/m^).

NYC / ER (Oct 29) - Particulate Monitoring (PM2 5) o Pace University (Site 1) - 24-hr average concentration for this period was 21.81 ug/m\ o Manhattan Boro Community College (Site 2) - 24-hour average concentration for this period was 15.09 ug/m\ o Coast Guard Building - Battery Park (Site 3) - 24-hour average concentrations for this period was 13.16 ug/m’. o All readings below the National Ambient Air Quality Standard for PM2 5 (65 ug/m’).

NYC / ER (Oct 29) - Volatile organics (TAGA) o Benzene exceeded O SHA TWA PEL (1 ppm) at one location (North Tower) on the debris pile in the plume at ground level. o Benzene levels on the debris pile are significantly reduced from those noted over the past week. o 2 samples (Austin Tobin Plaza and North Park Pier - TAGA Location) did not note any benzene above the detection lim it (20 ppbv). o Chlorodifluoromethane (Freon-22) was detected and confirmed in the North Tower debris pile (210 ppbv) at ground level. o Chlorodifluoromethane levels were well below the NIOSH REL TWA of 1,000 ppm.

NYC / ER (Oct 14 - Oct 23) - Asbestos Monitoring (Particulate Monitoring Stations) o Monitoring sites include: Pace University (Site 1) Manhattan Boro Community College (Site 2) Coast Guard Building: Battery Park (Site 3) Public School 154: 333 East 135^ St. Bronx (Site 5) Intermediate School 143: 511 West 182"^ St., Manhattan (Site 6) Public School 274: 800 Bushwick Ave., Brooklyn (Site 7) Public School 44: 80 Maple Parkway. Staten Island (Site 8)

CITY_21MC100_002458868

NYC-WTC_000321278

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000321278Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000321168

Asbestos sampling results; routine monitoring with mostly below-standard values.

Similar indexed content

Compare copies and versions →