Air Sampling, NYC/ER, Oct 29–Nov 1 2001

Machine-extracted title · confidence 38%

Asbestos sampling results; routine monitoring with mostly below-standard values.

NYC-WTC_000321168–000321170
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Fresh Kills (Oct 31, 1800 - Nov 1, 0806) - Asbestos o All 18 samples analyzed were below the TEM AHER A standard. o 1 sample (“Sift” Location #9A) was not analyzed due to pump failure (results deemed invalid). o Note: Low sample volumes recorded.

Ambient Air Sampling Locations

NYC / ER (Nov 1) - Particulate Monitoring (Dataram ) o Particulate levels noted at thr ee locations (Stations L, N, R) were below the OSHA TWA. o Instruments operated approximately 8 hours. o Station L values ranged from 0.0 to 62.5 ug/m 'with an average of 37.5 ug/m’. o Station N values ranged from 0.0 to 56.0 ug/m’ with an average of 39.2 ug/m’. o Station R values ranged from 56.5 to 72.1 ug/m’ with an average of 58.0 ug/m’. o Dataram readings for the period Oct 26'*’ through Oct 3 F‘ were determined to be unuseable.

NYC / ER (Oct 31) - Particulate Monitoring (PM2 5) o Pace University (Site 1) - 24-hr average concentration for this period was 8.93 ug/m^. o Manhattan Boro Community College (Site 2) - 24-hour average concentration for this period was 10.27 ug/m^. o Coast Guard Building - Battery Park (Site 3) - 24-hour average concentrations for this period was 11.74 ug/m\ o All readings below the National Ambient Air Quality Standard for PM2 5 (65 ug/m’).

NYC / ER (Nov 1) - Particulate Monitoring (PM2 5) o Pace University (Site 1) - 24-hr average concentration for this period was 22.35 ug/m\ o Manhattan Boro Community College (Site 2) - 24-hour average concentration for this period was 26.57 ug/m^. o Coast Guard Building - Battery Park (Site 3) - 24-hour average concentrations for this period was 21.31 ug/m^. o All readings below the National Ambient Air Quality Standard for PM2 5 (65 ug/m ').

NYC / ER (Nov 1) - Volatile organics (TAGA) o Benzene exceeded O SHA TWA PEL (1 ppm) at one location (South Tower) on the debris pile in the plume at ground level. o 1 of 3 other samples (North Park Pier) did not note any benzene above the detection limit (20 ppbv). o Chlorodifluoromethane (Freon-22) was detected and confirmed in the North Tower debris pile (960 ppbv) at ground level. o Chlorodifluoromethane levels were well below the NIOSH REL TWA of 1,000 ppm.

CITY_21MC100_000948481 NYC-WTC_000321169

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000321169Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000321139

Asbestos air sampling results and exceedances at perimeter and indoor locations, Nov 5–8.

Similar indexed content

NYC-WTC_000321177

Asbestos sampling with pump faults noted and several locations below standard; plus outdoor monitoring.

Similar indexed content

NYC-WTC_000321183

Asbestos sampling results; multiple days with results below standard; occasional pump faults noted.

Similar indexed content

EPA air sampling status report, Mar 2002

NYC-WTC_000196433

Status report on asbestos air sampling results from the EPA indicating samples were below TEM AHERA standards in March 2002.

Similar indexed content