EPA air/bulk sampling, Oct 25, 2001

Machine-extracted title · confidence 46%

Asbestos sampling results and locations; several locations below TEM AHERA standard.

NYC-WTC_000287593–000287595
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Fresh Kills (Oct 22, 0630 - 1900) - Asbestos

o All 18 samples analyzed were below the TEM AHERA standard. o 1 sample T Location # 16 was not analyzed due to overloading of particles.

Fresh Kills (Oct 23, 0700 - 1830) - Asbestos

o All 19 samples analyzed were below the TEM AHERA standard.

Fresh Kills (Oct 23, 1800 - Oct 24, 0600) - Asbestos

o All 19 samples analyzed were below the TEM AHERA standard.

Ambient Air Sampling Locations

NYC/ER(Oct ll)-PCBs

o Trace amounts detected in 3 of 10 samples. o 7 samples did not detect any PCBs. o All concentrations are below the EPA Removal Action level guidelines.

NYC / ER (Oct 24) - Particulate Monitoring (Dataram) o Particulate levels noted at three locations (Stations L, N, R) were below the OSHA TWA. o Instruments operated approximately 6 hours. o Station L values ranged from 74.0 to 99.1 ug/m3 with an average of 74.1 ug/m\ o Station N values ranged from 62.6 to 69.7 ug/m3 with an average of 62.7 ug/m\ o Station R values ranged from 56.5 to 78.0 ug/m3 with an average of 65.1 ug/m\

NYC / ER (Oct 24) - Volatile organics (TAGA)

o Benzene exceeded OSHA TWA PEL (1 ppm) at two locations on the debris pile in the plume at ground level. o Chlorodifluoromethane (Freon-22) continues to be noted as a Tentatively Identified Compound (TIC) in samples collected from the debris pile (North Tower and South Tower) in the plume at ground level. o Analytical standard required to confirm both the presence of Freon-22 and it’s concentration.

NYC / ER (Sep 28 - Oct 13) - Asbestos Monitoring (Particulate Monitoring Stations) o Monitoring sites include: Pace University (Site 1) Manhattan Boro Community College (Site 2) Coast Guard Building: Battery Park (Site 3) Public School 154: 333 East 135**’ St. Bronx (Site 5) Intermediate School 143: 511 West 182"** St.. Manhattan (Site 6) Public School 274: 800 Bushwick Ave.. Brooklyn (Site 7) Public School 44: 80 Maple Parkway. Staten Island (Site 8) Public School 199: 3290 - 48* Ave.. Queens (Site 9) o During this period a total of 98 samples were collected from these monitoring sites. o 1 sample collected from rooftop of Site 2 (104.99 S/mmQ over a 12-hour period exceeded TEM AHERA standard on Oct 9*.

CITY_DEP_WORBY_CANNATA_SUBP_000030164

NYC-WTC_000287594

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000287594Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

Air sampling locations, Oct 2001 · Box unavailable

NYC-WTC_000321276

NYC/ER and NJ/ER asbestos monitoring; some locations not sampled due to pump/malfunction; one exceedance at indoor wash location.

10 shared non-person entities · 1 shared topics · similarity 0.981

machine-extracted · confidence unavailable · Check page ↗

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000280695

EPA air sampling results for asbestos at NYC ER and Fresh Kills locations; below standard findings.

Similar indexed content

Air sampling locations, Oct 2001

NYC-WTC_000321276

NYC/ER and NJ/ER asbestos monitoring; some locations not sampled due to pump/malfunction; one exceedance at indoor wash location.

Similar indexed content

Compare copies and versions →