NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 3 pages

EPA air sampling, Oct 19, 2001

Machine-extracted title · confidence 46%

Asbestos air sampling results for NYC ER and NJ; some samples not analyzed due to pump issues.

NYC-WTC_000287607–000287609
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

• NYC / ER (Oct 11)- Metals o Ten samples collected. o All metals were either not detected or were below applicable EPA Removal Action level guidelines, OSHA PELs, and the NAAQS for lead. o Note: Further QA/QC review of chromium in air analytical data generated in the past for the WTC monitoring effort, including the results for Oct 11% has revealed that chromium is not present in these samples. This includes the results for samples collected on Sep 16% Sep 23"*, Sep 27*, Oct 2"^ and Oct 4*.

• NYC / ER (Oct 8) - PCBs o Trace amounts detected in 4 of 10 samples well below levels of concern. o 6 samples did not detect any PCBs. o All levels are below the EPA Removal Action level guidelines.

NYC / ER (Oct 2) - Silicates

o All 10 samples did not detect any silicates.

NYC / ER (Oct 4) - Silicates o All 10 samples did not detect any silicates. NYC / ER (Oct 17) - Particulate Monitoring (PM2 5) o Pace University (Site 1) - 24-hr average concentration for this period was 15.50 ug/nr’ o Manhattan Boro Community College (Site 2) - 24-hour average concentration for this period was 6.52 ug/m^. o Coast Guard Building - Battery Park (Site 3) - 24-hour average concentrations for this period was 5.18 ug/m\ o All readings below the National Ambient Air Quality Standard for PM2 5 (65 ug/m ’). NYC / ER (Oct 18) - Particulate Monitoring (Dataram) o Particulate levels noted at three locations (Stations L, N, R) were below the OSHA TWA. o Instruments operated between 8 to 9.5 hours. o Station L values ranged from 0 to 37.4 ug/m3 with an average of 17.8 ug/m3. o Station N values ranged from 4.4 to 23.9 ug/m3 with an average of 8.8 ug/m3. o Station R values ranged from 7.2 to 71.2 ug/m3 with an average of 10.9 ug/m3. NYC / ER (Oct 18) - Volatile organics (TAGA) o These samples, and all those previously collected for VOC analysis via GC/MS in the TAGA, represent grabs collected over a period of a few minutes. The analytical results should be viewed in that context. o Benzene exceeded OSHA TWA PEL (1 ppm) at one location on the debris pile in the plume at ground level. NOTE: benzene PEL was previously identified as 0.5 ppm. This concentration actually represents an OSHA action level used to trigger certain monitoring requirements. o Overall VOC levels in the debris pile improved significantly from previous results.

CITY_21MC100_002417140

NYC-WTC_000287608

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000287608Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Air sampling locations, Oct 2001 · page 3

NYC-WTC_000321276

NYC/ER and NJ/ER asbestos monitoring; some locations not sampled due to pump/malfunction; one exceedance at indoor wash location.

Similarity score 0.977 (not a probability)

machine-extracted · confidence unavailable · Check page ↗

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000307496

EPA/ER bulk air sampling results with below-standard AHERA findings and updates.

Similar indexed content

NYC-WTC_000318160

Asbestos air sampling locations and results; all samples below standard with one indoor exceedance noted.

Similar indexed content

Compare copies and versions →