Air Sampling Locations, asbestos, Dec 2001

Machine-extracted title · confidence 28%

Air sampling locations for asbestos in NYC/ER; notes on several samples not collected.

NYC-WTC_000321205–000321207
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

[.Jessica Leighton - RA sitrep12-12.wpd Page 3 |

isocyanate) (MDI), and toluene-2,4-diisocyanate (TDI). o Locations monitored for the cyanide compounds included: northwest comer of North Tower, Austin Tobin Plaza near the barrier of the inner work zone, southeast comer of South Tower (30 feet below street level), the southwestern barrier of the iimer work zone at West St./Liberty St., and Locations A, B, C, D, E, P, R, S, 3B from the fixed ambient air sampling stations. o Measurements for cyanide compounds at the four work-zone locations consisted of a 30-35 minute continuous run at each location. o Monitoring at the four work-zone locations revealed the presence of low levels of HDI and TDI. o As a point of comparison, all levels detected were below the respective OSHA PELs and NIOSH RELs for these compounds. The NIOSH REL for HDI is 0.005 ppm. The OSHA PEL for TDI is 0.02 ppm. o Note: The cassettes used to monitor for these cyanide compounds also respond positively to elevated levels of chlorine, nitrogen dioxide, nitric oxide, and ozone. o Field observations during this sampling event noted the presence of heavy machinery/metal cutting as possible sources of analytical interference.

o Note: Air samples (15-minute grabs) were collected for fixed laboratory analysis at two of the work-zone locations (northwest comer of North Tower, and southwestern barrier of the inner work zone at West St./Liberty St.) and at each of the fixed ambient air sampling stations. Results are pending. o Measurements for the cyanide compounds at the fixed ambient air sampling stations consisted of one 3-minute run taken once that day at each of the locations. o The results from the monitoring at the fixed ambient air sampling stations have not been received from the field.

CITY_21MC100_002458782

NYC-WTC_000321207

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000321207Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000321198

Asbestos air sampling locations and kills data; mentions data quality issues.

Similar indexed content

Compare copies and versions →