NYC / ER (Dec 6) - Particulate Monitoring (Dataram)
o Particulate levels noted at three locations (Stations L, N, R) were below the OSHA
TWA.
o Instruments operated approximately 6.5 hours.
o Station L values ranged from 5.9 to 134.8 ug/m’ with an average of 39.9 ug/m’.
o Station N values ranged from 10.0 to 205.3 ug/m’ with an average of 32.6 ug/m\
o Station R values ranged from 0.1 to 104.7 ug/m’ with an average of 31.1 ug/m’.
NYC / ER (Dec 6) - Volatile Organics (Mobile Laboratory)
o Benzene exceeded OSHA TWA PEL (1 ppm) at one location (North Tower) in the
debris area in the plume at ground level.
o 2 of the 3 other samples (Wash Tent and Austin Tobin Plaza) did not note any
benzene above the detection limit (20 ppbv).
Direct Reading Instruments
NYC / ER (Dec 4)
0 Monitoring for hexamethylene diisocyanate (detection limit = 1 ppb), methylene
bisphenyl isocyanate (detection limit = 2 ppb), and toluene-2,4-diisocyanate
(detection limit = 2 ppb) did not detect any of those compounds.
o Locations monitored for cyanide compounds included: Locations A, B, C, D, E, P, R,
S, 3B from the fixed ambient air sampling stations.
o Measurements for the cyanide compounds consisted of one 3-minute run taken twice
that day at each of the locations.
o Data not attached.
NYC/ER (Dec 6)
o Nothing of significance reported with routine daily monitoring parameters.
o Monitoring for hexamethylene diisocyanate (detection limit = 1 ppb), methylene
bisphenyl isocyanate (detection limit = 2 ppb), and toluene-2,4-diisocyanate
(detection limit = 2 ppb) did not detect any of those compounds.
o Locations monitored for the cyanide compounds included: north side of North Tower,
Austin Tobin Plaza near the barrier of the inner work zone, southeast comer of South
Tower, the western barrier of the inner work zone at West St./Liberty St., and
Locations A, B, C, D, E, P, R, S, 3B from the fixed ambient air sampling stations.
o Measurements for cyanide compoimds at the first four locations consisted of a 30-35
minute continuous run at each location.
o Measurements for the cyanide compounds at the fixed ambient air sampling stations
consisted of one 3-minute run taken twice that day at each of the locations.