NYC 9/11 Public Portal Document
[Jessica Leighton - RA sitrep12-07.wpd Page 2 |
o Park Row (Site 1) - 24-hr average concentration for this period was 20.32 ug/m\
o Chambers St./West St. (Site 2) - 24-hour average concentration for this period was
20.50 ug/m^.
o Coast Guard Building - Battery Park (Site 3) - 24-hour average concentrations for this
period was 18.86 ug/m\
o Wall Street - 24-hour average concentrations for this period was 22.58 ug/m\
o All readings below the National Ambient Air Quality Standard for PM2.5 (65 ug/m’).
NYC / ER (Dec 4) - Particulate Monitoring (TEOM PM 2.5)
o Park Row (Site 1) - 24-hr average concentration for this period was 25.69 ug/m\
o Chambers St./West St. (Site 2) - 24-hour average concentration for this period was
23.14 ug/m\
o Coast Guard Building - Battery Park (Site 3) - 24-hour average concentrations for this
period was 24.37 ug/m^.
o Wall Street - 24-hour average concentrations for this period was 25.17 ug/m^.
o All readings below the National Ambient Air Quality Standard for PM2 5 (65 ug/m’).
NYC / ER (Dec 5) - Particulate Monitoring (TEOM PM 2.5)
o Park Row (Site 1) - 24-hr average concentration for this period was 26.22 ug/m\
o Chambers St./West St. (Site 2) - 24-hour average concentration for this period was
27.94 ug/m\
o Coast Guard Building - Battery Park (Site 3) - 24-hour average concentrations for this
period was 23.65 ug/m\
o Wall Street - 24-hour average concentrations for this period was 24.77 ug/m^.
o All readings below the National Ambient Air Quality Standard for PM2.5 (65 ug/m’).
NYC / ER (Dec 3) - Particulate Monitoring (TEOM PMio)
o Wall Street - 24-hour average concentrations for this period was 39.06 ug/m\
o All readings below the National Ambient Air Quality Standard for PMi 0 (150 ug/m').
NYC / ER (Dec 4) - Particulate Monitoring (TEOM PMio)
o Wall Street - 24-hour average concentrations for this period was 46.77 ug/m^.
o All readings below the National Ambient Air Quality Standard for PMio (150 ug/m’).
NYC / ER (Dec 5) - Particulate Monitoring (TEOM PMio)
o Wall Street - 24-hour average concentrations for this period was 49.14 ug/m^.
o All readings below the National Ambient Air Quality Standard for PMio (150 ug/m’).
CITY_21MC100_002458777
NYC-WTC_000321199
OCR can misread numbers and units. Confirm readings against the page image before using them.