NYC 9/11 Public Portal Document
NYC / ER (Dec 25) - Particulate Monitoring (Dataram)
o No monitoring conducted.
NYC / ER (Dec 26) - Particulate Monitoring (Dataram)
o Particulate levels noted at three locations (Stations L, N, R) were below the OSHA
TWA.
o Instruments operated approximately 6‘A to 7 hours.
o Station L values ranged from 3.2 to 268.5 ug/m" with an average of 17.7 ug/m\
o Station N values ranged from 62.9 to 870.8 ug/m" with an average of 75.2 ug/m\
o Station R values ranged from 4.0 to 1316.2 ug/m' with an average of 21.0 ug/m\
NYC / ER (Dec 19) - Volatile Organics (Mobile Laboratory)
o Benzene did not exceed OSHA TWA PEL (1 ppm) at any of the four locations
monitored, including in the debris area at ground level.
o Benzene was not detected above the detection limit (20 ppbv) in 2 of the 4 locations
monitored (Washing Tent, Austin Tobin Plaza), including in the debris area at ground
level.
NYC / ER (Dec 20) - Volatile Organics (Mobile Laboratory)
o Benzene exceeded OSHA TWA PEL (1 ppm) at one location (South Tower) in the debris
area at ground level,
o 2 of the 3 other samples (Wash Tent, Austin Tobin Plaza) did not note any benzene above
the detection limit (20 ppbv).
NYC / ER (Dec 21) - Volatile Organics (Mobile Laboratory)
o Benzene did not exceed OSHA TWA PEL (1 ppm) at any of the four locations
monitored, including in the debris area at ground level.
o Benzene was not detected above the detection limit (ranging from 20 ppbv to 250 ppbv)
in 3 of the 4 locations monitored (Washing Tent, Austin Tobin Plaza, South Tower),
including in the debris area at ground level.
NYC / ER (Dec 22) - Volatile Organics (Mobile Laboratory)
o Benzene exceeded OSHA TWA PEL (1 ppm) at one location (South Tower) in the debris
area at ground level.
o 2 of the 3 other samples (Wash Tent, Austin Tobin Plaza) did not note any benzene above
the detection limit (20 ppbv).
NYC / ER (Dec 23) - Volatile Organics (Mobile Laboratory)
o Benzene exceeded OSHA TWA PEL (1 ppm) at one location (North Tower) in the debris
area at ground level.
o 2 of the 3 other samples (Wash Tent, Austin Tobin Plaza) did not note any benzene above
the detection limit (20 ppbv).
NYC / ER (Dec 24) - Volatile Organics (Mobile Laboratory)
CITY_21MC100_002417062
NYC-WTC_000287353
OCR can misread numbers and units. Confirm readings against the page image before using them.