NYC 9/11 Public Portal Document
o No samples collected during this period due to weather conditions.
NYC / ER (Dec 25) - Volatile Organics (Mobile Laboratory)
o No samples collected during this period.
NYC / ER (Dec 26) - Volatile Organics (Mobile Laboratory)
o Benzene exceeded OSHA TWA PEL (1 ppm) at one location (North Tower) in the debris
area at ground level.
o All 3 of the other samples (Wash Tent, Austin Tobin Plaza) did not note any benzene
above the detection limit (ranging from 20 ppbv to 50 ppbv).
Direct Reading Instruments
NYC/ER (Dec 19)
o Nothing of significance reported with routine daily monitoring parameters.
o Monitoring conducted for hexamethylene diisocyanate (HDl), methylene bis(4-phenyl
isocyanate) (MDI), and toluene-2,4-diisocyanate (TDI).
o Locations monitored for the cyanide compounds included: North Tower, South Tower,
Vista Hotel, Building No. 4, and Locations A, B, C, D, E, P, R, S, 3B from the fixed
ambient air sampling stations.
o Measurements for the cyanide compounds consisted of one to three 3-minute run(s) taken
once that day at each of the locations.
o Low levels of HDI, MDI, and/or TDI identified at the North Tower, South Tower, Vista
Hotel, and Location B (Note: not all compounds were identified at each of the locations).
O The MDI and TDI hits were all measured at or below the detection limit (2 ppb).
o As a point of comparison, all levels detected were below the respective OSHA PELs and
NIOSH RELs for these compounds. The NIOSH REL for HDI and MDI is 0.005 ppm.
The OSHA PEL for TDI is 0.02 ppm.
o Note: The cassettes used to monitor for these cyanide compounds also respond positively
to elevated levels of chlorine, nitrogen dioxide, nitric oxide, and ozone.
o Note: Air samples (15-minute grabs) were collected for fixed laboratory analysis at two
of the work-zone locations and at each of the fixed ambient air sampling stations. Results
are pending.
NYC / ER (Dec 20)
o Nothing of significance reported.
NYC/ER(Dec 21)
o Nothing of significance reported.
NYC / ER (Dec 22)
o Nothing of significance reported.
NYC / ER (Dec 23)
CITY_21MC100_002417063
NYC-WTC_000287354
OCR can misread numbers and units. Confirm readings against the page image before using them.