NYC 9/11 Public Portal Document
Asbestos Air Monitoring Data Summary for Lower Manhattan WTC Sampling
Totals (for sampling through 01/29/02, in s/mm2)
Total Samples 5517
Samples Above Screening Level 15
% Above 0. 27 %
Samples Below 5502
Maximum Value (12/04/01); 204.44
Minimum Value: Not Detected
Screening Level*: 70
Average All 10.54
0%
■ Samples Above
Screening Level - All
Louver Manhattan Sites
■Samples ^elow
lOOW The level of concern for asbestos is
based on continuous exposure to
more than 70 structures per square millimeter for an extended period. In evaluating data from
the World Trade Center and the surrounding areas, EPA is using a protective standard under
AHERA, the Asbestos Hazard Emergency Response Act, to evaluate the risk from asbestos in
the outdoor and indoor air. This is a very stringent standard that is used to determine whether
children may re-enter a school building after asbestos has been removed or abated. It is based
on assumptions of long-term exposure. EPA has chosen to use this standard, because it is the
most stringent and protective, even though it is unlikely that the public will be exposed to
asbestos from the World Trade Center site for extended periods of time.
To determine asbestos levels, air filters are collected from monitoring equipment through which
air in the school building has passed and viewed through a microscope. The number of
structures - material that has asbestos fibers on or in it - is then counted. The measurements
must be 70 or fewer structures per square millimeter before children are allowed inside.
There is also a federal standard for asbestos exposure under OSHA, the Occupational Safety
and Health Act, which is used to protect workers on-the-job. The standard is .1 fiber per cubic
centimeter averaged over an eight-hour day. To be as protective as possible, EPA is using the
school re-entry standard in tests around the World Trade Center. Levels above 70 structures
per square millimeter do NOT imply an immediate health threat. Asbestos exposure becomes a
health concern when high concentrations of asbestos fibers are inhaled over a long period.
Illness is very unlikely to result from a single, high-level exposure, or from a short period of
exposure to lower levels.
CITY_21MC100_002458622