NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 3 pages

Air monitoring in Lower Manhattan

Machine-extracted title · confidence 49%

DEP report on outdoor ambient asbestos monitoring and indoor re-occupancy criteria.

NYC-WTC_000320669–000320671
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Air Monitoring in Lower Manhattan http://www.nyc.gov/httnl/dep/html/airmonit.html

www.nyc.gov/html/dep/html/airmonit.html ||

.Dsapl The City of New York Department of Environmental Protection

Air, Noise and Hazardous Materials :«u

Air Monitoring in Lower Manhattan DEP is monitoring the ambient outdoor air for asbestos. This effort is augmenting School ambient air asbestos sampling being done by the EPA and other state and city agencies. Data There is currently no outdoor ambient standard for asbestos. The US and NYC standard I for asbestos in community and residential buildings is 0.01 fibers/cubic centimeter (fed in ={?« I ^odoor air. An indoor area which has had asbestos detected and then removed must show that I air samples are at or below the 0.01 fee standard before the indoor area can be re-occupied. I Although the ambient outdoor air is being monitored, DEP is using this value as a way to I characterize the levels of asbestos in the air.

Since the measurement protocol used, phase contrast microscopy (PCM), counts fibers, DEP is also conducting an additional analysis for all samples that are above 0.01 fee. This measurement protocol is called transmission electron microscopy (TEM) and counts the number of asbestos fibers in the sample. EPA is reporting their data in TEMs, and provides a good explanation of the interpretation of the standard that uses this methodology on their website.

Results indicate that, as expected, asbestos is present in some of the debris at the site and in areas very close to the site. Between September 28, 2001 and the present, the vast majority of air sampling results outside the security zone have been below the standards for asbestos in indoor air.

As testing continues, there may be the possibility of occasional short-term increases in levels of asbestos in the air above the residential standard of 0.01 f/cc of air. When the measured level for the outdoor ambient air is above 0.01 fee, the samples will be analyzed to determine how many of the fibers are actually asbestos fibers.

To view recent air monitoring results, click on a sampling location below or on the map (Links wiii open in a new browser window);

1 of 3 2/9/02 2:59 PM

CITY_2IMCl0 0_0 0 0 9 3 8 614 NYC-WTC_000320669

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000320669Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

IRIS asbestos summary (draft)

NYC-WTC_000338416

Draft IRIS summary page for Asbestos (CASRN 1332-21-4) with exposure information.

Similar indexed content

Compare copies and versions →