NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 3 pages

Air Monitoring in Lower Manhattan, DEP overview, 2002

Machine-extracted title · confidence 42%

City DEP outdoor ambient air monitoring for asbestos; standards and occupancy guidance.

NYC-WTC_000387635–000387637
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document Air Monitoring in Lower Manhattan Page 1 of3

The City of New York t of Environmental Protection

I •' AfeeUEDEgfJ Environmental Compliance “ StKPOiiV

Air Monitoring in Lower Manhattan •'".1 DEP is monitoring the ambient outdoor air for asbestos. This effort is augmenting ambient air asbestos sampling being done by the EPA and other state and city agencies. There is currently no outdoor ambient standard for asbestos. The US and ; firn: j NYC standard for asbestos in community and residential buildings is 0.01 fibers/cubic centimeter (fee) in indoor air. An indoor area which has had asbestos detected and then removed must show that air samples are at or below the 0.01 fee standard before the indoor area can be re-occupied. Although we are ■; Forms ■ 1 • • Ci'AWide -J monitoring the ambient outdoor air, we are using this value as a way to i Aecoti'atabiliiS characterize the levels of asbestos in the air. Since the measurement protocol used, • Sireaui phase contrast microscopy (PCM), counts fibers, we are doing an additional ? uCafflaa^afi^a analysis for all samples that are above 0.01 fee. This measurement protocol is 5 called transmission electron microscopy (TEM) and counts the number of asbestos fibers in the sample. Our TEM results will be added shortly. EPA is reporting their data in TEMs, and provides a good explanation of the interpretation of the standard that uses this methodology on their website. IfeiN EduSEloy J ■ihlaQQ^sU Results indicate that, as expected, asbestos is present in some of the debris at the site and in areas very close to the site. As of September 28,2001, most air sampling results outside the security zone were below the standards for asbestos in ■................... • '.-'J • Gofliact Us I indoor air.

b As testing continues, there may be the possibility of occasional short-term increases in levels of asbestos in the air above the residential standard of 0.01 fibers per cubic centimeter of air. When the measured level for the outdoor ambient air is above .01 fee, the samples will be analyzed to determine how many of the fibers are actually asbestos fibers.

To view recent air monitoring results, click on a sampling location below or on the map:

Sampling Site Location 1 W.BROADWAY 19 VESEY & & WORTH ST WEST ST, 2 BROADWAY & 20 VESEY WORTH ST BETWEEN CHURCH & GREENWICH ST http://www.nyc.gov/html/dep/html/airmonit.html 10/18/01

CITY_21MC100_002821722

NYC-WTC_000387635

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000387635Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →