NYC 9/11 Public Portal Document
Oxides of Nitrogen/
Sulfur: . Sampling on grappler operators on the rubble pile, and on employees at the
truck wash stations revealed trace levels of nitric oxide and nitrogen
dioxide. SO2 personal and area results were found to be below OSHA
limits.
Metals: OSHA has taken a total of 1035 samples (excluding bulk and blank samples)
to monitor worker exposures to dusts, fumes, oxides, and other compounds
of metals such as antimony, beryllium, chromium, cobalt, copper, iron, lead,
manganese, mercury, molybdenum, nickel, vanadium, zinc, cadmium,
magnesium, and arsenic. Results from these samples are generally well
below the applicable OSHA limits. However, torch cutting and burning
structural steel at the nibble pile have resulted in instances of overexposures
as follows: copper (13); iron oxide (26); lead (14); and cadmium (2).
Accordingly, OSHA is recommending that workers engaged in these
operations wear appropriate respiratory protection. See information below
for the specific counts in regards to mercuiy.
Mercury OSHA has taken 224 air samples for inorganic mercury. Results for 224 of
those air samples have been received and no mercury was detected. Also, 36
bulk samples previously collected from nibble were re-analyzed for mercury
and none was detected. Additionally, 10 bulks were taken on 1/3, with one
(1) sample detecting mercury at 0.9ppm and nine (9) samples being non
detected. 38 bulk samples were taken beRveen 1/8 and 1/11/02; results
indicate 0.1 to 0.2 ppm mostly in around the footprint of Bldg.-6, and in the
pit between WTC tower 1&2.
Ionizing Radiation; A survey of the nibble pile was conducted on 10/22-10/23 to check for latent
radiation with particular attention to alpha radiation. Results show no
elevated levels of concern from either known building latent radiation
sources or any terrorist origin source materials.
Page 4 of 4
CITY_21MC1OO_OO3O35524
NYC-WTC_000320560
OCR can misread numbers and units. Confirm readings against the page image before using them.