Dioxins: OSHA has taken 10 dioxin samples (excluding blanks) in the plume over hot
spots in (and around the perimeter of) the rubble pile. Dioxin levels detected
around the perimeter are lower than those found directly over the pile. To
date, only one sample taken on the rubble pile showed dioxin levels which
exceeded background levels. Dioxins are considered collectively as suspect
human carcinogens. OSHA does not have a PEL for dioxins.
Polynuclear Aromatic
Hydrocarbons OSHA has taken 110 samples (excluding blanks). The majority of the samples .
have not shown the presence of benzo(a)pyiene and/or one or more of five
additional fused polycyclic hydrocarbons: anthracene, acridine, pyrene, clrysene
and phenanthrene. Sample results to date have identified eight samples which
reached or exceeded OSHA’s coal tar pitch volatile PEL of 0.2mg/m’. These
personal samples were taken on the pile on iron workers and grappler operators.
OSHA continues to strongly recommend the use of respiratory protection when
working on the rubble pile.
Freon R-22,
Hydrogen Fluoride
Phosgene: OSHA has taken a total of 202 samples for Freon R-22
(chlorodiflouromethane), hydrogen fluoride, and phosgene. Only one Freon
sample resulted in a detectable level of 6.4 ppm during the transfer of Freon
from the auxiliary chiller, and all other samples were none-detected. OSHA
does not have an exposure limit for Freon R-22. (The NIOSH REL for
Freon is lOOOppm..) Sampling for the decomposition products of Freon R-
22, hydrofluoric acid (HF) and phosgene showed no detectable levels.
Inorganic Acids OSHA has taken approximately 97 samples for inorganic acids such as
hydrochloric, phosphoric, and sulfuric acids. Two samples for sulfuric acid
were found to exceed OSHA’s pemiissible exposure limit (PEL) of 1 mg/m\
Page 3 of 4
CITY_21MC1OO_OO3O35523
NYC-WTC_000320559
OCR can misread numbers and units. Confirm readings against the page image before using them.