NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 4 pages

OSHA asbestos sampling data, 9/26/2001

Machine-extracted title · confidence 35%

Air and TEM/PCM results for area samples at WTC rubble pile on 9/26/01; asbestos fibers quantified.

NYC-WTC_000388969–000388972
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

OSHA SAMPLING RESULTS SUMMARY AS OF 2IQIQ2

Asbestos: A total of 989 samples (excluding bulk and blank samples) for asbestos have been taken. From 9/13 -9/21, 177 samples were taken in the financial district. They were taken on OSHA personnel as they walked within certain predetermined zones. Results revealed asbestos concentrations ranging from ND (none detected) to .037 f/cc., well below OSHA’s permissible e.xposure limit (PEL) of 0.1 Fee. After 9/21, sampling focused on the rubble pile and those workers working on or immediately next to it. 132 of the samples analyzed exceeded OSHA’s limit via PCM analysis. However, upon further analysis using discriminating counting methods and/or TEM analysis, the number of asbestos fibers found dropped dramatically to below detectable levels or well below .1 f/cc.

Carbon Monoxide: A total of 108 personal samples of workers on the rubble pile showed results ranging from 1 ppm to 34 ppm which are well below the OSHA permissible exposure limit of 50 PPM.

Noise: OSHA is monitoring the noise exposures of employees who perfonn (or work near) noisy operations such as jack hammering and drilling. To date the 94 samples collected indicate that employee noise exposures range from 73.7 dBA to 94.5 dBA. One personal sample and one area sample taken during core drilling operations have exceeded tlie applicable permissible exposure limit of 90 dBA. Accordingly, OSHA continues to recommend the use of appropriate hearing protection in noisy operations.

T otal Dust (PNOR) A total of 109 samples (excluding bulk and blank samples) for total dust in and around the rubble pile were taken. Two samples were found to be in excess of the PEL for Total dust (15mg/m3). The highest exposure was found on one operator who was exposed at approximately 4X PEL.

Page I of 4

CITY_21MC100_002912868

NYC-WTC_000388969

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000388969Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Page similarity is temporarily unavailable or this page has no indexed vector.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →