NYC-WTC_000337528
WTC monitoring sampling and analytical parameters; test method overview.
7 shared non-person entities · 1 shared topics · similarity 0.980
machine-extracted · confidence unavailable · Check page ↗Memo describing VOC monitoring near WTC site and related exposure considerations.
NYC-WTC_000320377OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
WTC Indoor Air Monitoring - Sampling and Analytical Procedures Analytical Media Sampling Points Sampling Method Proposed Sampling Vulnerability/Practicality Analytical Method Proposed Parameters
"This test method does not describe procedures or techniques
7 Asbestos Microvac ASTM 5755-95 required to evaluate the safety or habitability of buildings with asbestos-containing materials, or compliance with federal, state, or local regulations or statutes. It is the user's responsibility to make ASTM 5755-95
4 these determinations." (Section 5.1.1 of method 5755-95)
Lead Microvac ASTM 5755-95“ NIOSH 7300 Carpets, fabric furniture or Porous Soft After speaking with several people in HQ and RTP, it does not drapery in areas of activity Still checking on methods. Reached surfaces appear there are standardized methods for the collection of these To be determined once the sampling method (if (living rooms, family roonre) Dioxins out to RTP and HQ. Waiting for parameters, rather many of the methods being used today are any) has be selected additional information research and development procedures.
PAHs
Silica
See the comment for asbestos. Samples will be combined with the MMVF Microvac ASTM 5755-95 EMSL MSD.0300 asbestos sampling.
"This test method does not describe procedures or techniques op Asbestos Wipe ASTM D 6480-99 or required to evaluate the safety or habitability of buildings with asbestos-containing materials, or compliance with federal, state, or ASTM D 6480-99 (wipe) or Microvac ASTM 5755-95 ASTM 5755-95 (microvac) local regulations or statutes. It is the user's responsibility to make these determinations.” (Section 5.1.1 of method 5755-95) Horizontal surfaces of Non-porous tables or counters and NIOSH 9100 None known, wipe sampling has been legally defended. SW-846 601 OB Lead Hard barefloors, ceilings and surfaces walls in areas of activity Dioxins ASTM D 6661-01 ASTM 6661-01/SW-846 8290 (living rooms, family rooms) PAHs ASTM D 6661-01 ASTM 6661-01/SW-846 8270C
See comment for silica above. See comment for silica above. Seecpmme'nfforsiiicaTabove^ Silica
Wipe ASTM D 6480-99 or Same as asbestos microvac. Samples will be combined with the MMVF EMSL MSD.0300 Microvac ASTM 5755-95 asbestos sampling. Air pump operated at lOL/min for 8 hours to achieve the PIC PCLShLlOSH 740aj31lawetf-6yTEM AHERA Asbestos NIOSH 7400 method. wkgroup detection limits O Air pump operated at lOL/min for 8 hours to achieve the PIC Lead NIOSH 7300 SW-846 601 OB H Areas of known activity wkgroup detection limits Indoor Air (living rooms, family rooms) Air pump operated at 2.5L/min for C hours to achieve the PIC Silica NIOSH 7500 NIOSH 7500 (XRD) wkgroup detection limits o Assumed that it behaves the same as asbestos, samples will be MMVF NIOSH 7400 EMSL MSD.0300 o combined with the asbestos sampling. o I o NOTE; All samples (cassettes and wipes) will be preweighed by the laboratory or supplier prior to sample collection. After sample collection and upon receipt of the samples by the laboratory, the laboratory will weigh the o co ; sample wipe or cassette prior to performing the analysis. O CO CT , “ This method is for asbestos and is being modified for the collection of lead dust. Modification - to use the filter specified for method NIOSH 7300 CO '
NYC-WTC_000320377
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000337528
WTC monitoring sampling and analytical parameters; test method overview.
7 shared non-person entities · 1 shared topics · similarity 0.980
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000353722
Overview page showing sampling, analytical notes and vulnerability considerations.
7 shared non-person entities · 1 shared topics · similarity 0.975
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000317655
Monitoring page detailing asbestos testing methods and parameters.
7 shared non-person entities · 1 shared topics · similarity 0.974
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000304311
Monitoring method statement noting asbestos material testing limitations and procedures.
7 shared non-person entities · 1 shared topics · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000408410
Notes on test methods and mycology/asbestos-related assessment; cautions about use.
7 shared non-person entities · 1 shared topics · similarity 0.988
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000196444
Document outlining monitoring parameters and referencing ASTM 5755-95 for asbestos-containing material evaluation at the WTC site.
7 shared non-person entities · 1 shared topics · similarity 0.988
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000196438
Documentation regarding asbestos monitoring methods and safety disclaimers for building habitability evaluation.
7 shared non-person entities · 1 shared topics · similarity 0.985
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000408629
WTC monitoring analytical method citation and limitations.
7 shared non-person entities · 1 shared topics · similarity 0.985
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000277655
Table of proposed sampling parameters and notes on method applicability.
7 shared non-person entities · 1 shared topics · similarity 0.983
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000304294
Document noting that test methods do not alone determine safety; emphasizes user responsibility for interpretations.
7 shared non-person entities · 1 shared topics · similarity 0.980
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000160235
EPA-distributed memo to federal, state and city agencies coordinating World Trade Center environmental response activities.
7 shared non-person entities · similarity 0.954
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000280220
Monitoring plan for WTC area sampling; micro vacuuming method and locations described.
7 shared non-person entities · 1 shared topics · similarity 0.945
machine-extracted · confidence unavailable · Check page ↗Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000304311
Monitoring method statement noting asbestos material testing limitations and procedures.
Similarity score 0.998 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000408410
Notes on test methods and mycology/asbestos-related assessment; cautions about use.
Similarity score 0.994 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000196444
Document outlining monitoring parameters and referencing ASTM 5755-95 for asbestos-containing material evaluation at the WTC site.
Similarity score 0.994 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000196438
Documentation regarding asbestos monitoring methods and safety disclaimers for building habitability evaluation.
Similarity score 0.993 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000408629
WTC monitoring analytical method citation and limitations.
Similarity score 0.992 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000277655
Table of proposed sampling parameters and notes on method applicability.
Similarity score 0.992 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000304311
Monitoring method statement noting asbestos material testing limitations and procedures.
Similar indexed content
NYC-WTC_000408410
Notes on test methods and mycology/asbestos-related assessment; cautions about use.
Similar indexed content
Document outlining monitoring parameters and referencing ASTM 5755-95 for asbestos-containing material evaluation at the WTC site.
Similar indexed content
NYC-WTC_000196438
Documentation regarding asbestos monitoring methods and safety disclaimers for building habitability evaluation.
Similar indexed content
NYC-WTC_000408629
WTC monitoring analytical method citation and limitations.
Similar indexed content