Draft: Do not Cite, Quote, or Release May 30, 2002 Last saved by CVLee

121 eyes during cleaning activities. 122

123 The dust samples were analyzed for the presence of asbestos and fibrous glass using 124 Polarized Light Microscopy (PLM). PLM can distinguish between fiber types by their 125 unique appearance and color when viewed under different wavelengths of light. In 126 addition, TEM analysis was conducted on all dust samples that showed asbestos content 127 by PLM as less than 1%. TEM analysis is very specific, can detect smaller fibers of 128 asbestos and is subject to less interference. This analysis was done to confirm the PLM 129 findings of no detectable asbestos. 130 131 The dust samples were also analyzed for mineral content using XRD as described above 132 for the air samples. For the dust samples, the mineral and the fiber results are expressed 133 as a percent, indicating the percent each component represents in the portion of the dust 134 sample analyzed. The different analytical techniques, XRD and microscopy (PLM, TEM, 135 SEM), help to characterize what was in the settled dust, however the results from the two 136 methods each performed on a portion of the dust collected, cannot simply be added 137 together to “sum up” what was in the dust. Each method reports the percentages based on 138 the specific dust portion analyzed. 139

140 Limitations 141

142 While the goal of the sampling was to evaluate the air and dust samples for a range of 143 contaminants, there is no one sample collection method or analysis that can provide all of 144 the determinations that were desired. The analysis strategy was to quickly identify what 145 components were present, in order to provide the public with information quickly should 146 any of the analyses reveal a significant concern. In order to strive for both of those goals, 147 some modifications to conventional protocols were made which limited some analyses to 148 determining the presence or absence of a component, and not the amount of the 149 component present. Whenever an analysis is expanded beyond its specific intent there is 150 the potential loss of sensitivity and an increase in the variability in the data. There are

CITy_21MC100_012171093

NYC-WTC_000320269

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000320269Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000275863

Investigation report on exposures to airborne and dust in Lower Manhattan.

Similar indexed content

NYC-WTC_000301668

Final report on airborne and [name] dust exposures in Lower Manhattan related to WTC events.

Similar indexed content

Compare copies and versions →