NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 69 pages

WTC airborne/dust exposure report draft, 2002

Machine-extracted title · confidence 30%

Draft report on potential exposures to airborne and settled surface dust in residential areas.

NYC-WTC_000320259–000320327
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Draft: Do not Cite, Quote, or Release May 30, 2002 Last saved by CVLee

151 also limitations in the data arising from quality control and tracking issues with sample 152 handling. While providing measured values for each of the components in air and dust 153 was the desired outcome, the uncertainty of the values obtained using modified protocols 154 is a significant concern. For some analytical results, this report treats the result for a 155 component as estimated values or as either detected (present) or non-detected (absent, but 156 possibly present in quantities too small to be seen with the methods). 157

158 Standards or health based guidance values 159

160 The New York City Department of Health in collaboration with ATSDR and several 161 other state and federal agencies developed screening guidelines for use in interpreting the 162 results of the sampling effort. Screening guidelines were developed for asbestos, 163 respirable silica, particulate matter, fibrous glass, and pH. If contaminants were below 164 screening guidelines, further health evaluation of the data was not considered to be 165 necessary. If guidelines were exceeded, additional review of the data and the sample 166 collection circumstances was conducted. If a guideline was exceeded, it does not 167 automatically indicate that a health concern exists. 168 169 Results: 170 Air Sampling 171

172 No airborne fibers (asbestos, fibrous glass, etc.) were detected above background levels in 173 any of the Lower Manhattan residential areas sampled during this investigation. Results 174 of the air sampling for fibrous glass showed that in lower Manhattan, fiberglass was 175 either not detected or was present at levels similar to those found in the comparison 176 buildings. Air sampling results for minerals detected quartz (silica) and other building- 177 related materials in lower Manhattan. The estimated concentrations of these minerals in 178 air were low. More samples were collected from lower Manhattan and more samples had 179 detectable quartz, calcite, port/lime, gypsum, mica, and halite than samples from the 180 comparison area. Five of the PM4 air samples with detectable crystalline quartz, had

CITY_21MC100_012171094

NYC-WTC_000320270

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000320270Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000275863

Investigation report on exposures to airborne and dust in Lower Manhattan.

Similar indexed content

NYC-WTC_000301668

Final report on airborne and [name] dust exposures in Lower Manhattan related to WTC events.

Similar indexed content

Compare copies and versions →