the same building should provide information the ranges found in indoor living spaces.

If the building is unoccupied, aggressive (leaf blower, high-power fan) indoor air sampling should be conducted. If the building is occupied, air sampling should be conducted with the building HVAC system in continuous operation. After sampling is completed, filters for the HVAC system, if applicable, should be inspected. If dust is present, recommend filter replacement.

Indoor air sampling will be conducted for: asbestos (NIOSH 7400 and, if an action level is exceeded, NIOSH 7402), PCMe), respirable crystalline silica (NIOSH 7500), and inhalable, thoracic, and respirable airborne particulate matter for fraction analyses of silica, gypsum, mica, etc. (lOM sampler).

Indoor floor dust sampling will be conducted for asbestos (via TEM as the detection limit for PLM is 1%); for silica, gypsum, mica (XRD); and for magnesium (EPA Method#). Floor dust sampling will be conducted using EPA’s Environmental Response Team (ERT) SOP for household dust collection. Any deviations from the SOP in actual field collection will be documented by the sampling team.

2. Exterior Air and settled dust sampling should occur in a grid pattern in residential areas.

Ambient air sampling will be conducted at breathing height for: asbestos (NIOSH 7400 and, if an action level is exceeded, NIOSH 7402), PCMe ), respirable silica (NIOSH 7500), and inhalable, thoracic, and respirable airborne particulate matter for fraction analyses of silica, gypsum, mica, etc. (lOM sampler). In addition, 24-hour real-time TSP, PMIO and PM 2.5 sampling will be conducted-again at breathing zone height.

Settled dust samples will be collected and analyzed for asbestos (via TEM as the detection limit for PLM is 1%); for silica, gypsum, and mica (XRD); and for magnesium (EPA Method #).

Page 6 of 10

CITY_21MC100_004067231

NYC-WTC_000320055

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000320055Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →