NYC-WTC_000317962
Lab evaluation of residential dust near WTC for asbestos and related contaminants (draft).
14 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗Draft ATSDR/DHAC evaluation of ambient and indoor dust near WTC with asbestos data.
NYC-WTC_000320050–000320058OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
V. Residence Selection/Sampling Rationale
The selection of priority residential areas should be decided upon by NYC DOH or the agency of their choosing, or by someone else on the scene with the concurrence of NYC DOH. Selection needs to be based on worst-case scenario(s) first, which will likely involve a visual determination (e.g., visible dust in lobby area, broken windows, dust along roadways and sidewalks). Worst case residential areas would include: A. Occupied and unoccupied residential areas closest to the WTC with visible exterior dust/fallout material B. Residential areas further from the WTC, where debris fallout may be tracked indoors C. Residential areas where Search/Rescue/Removal vehicles have spread dust that may be tracked indoors
Once residences are selected, then sampling can be pursued. If results of sampling in worst-case locations indicate no contaminants or respirable particle of present at levels of health concern, then residential sampling should be considered on a case-by-case basis (e.g., citizen complaint followed by a visual inspection).
If results in worst-case locations show indoor contamination/materials present at levels of concern, a thorough cleaning (these instructions need to be developed) should follow and the locations should be re-sampled. If the post-cleaning round of sampling indicates successful cleaning, then prior to sampling any additional residential locations (e.g., residential areas that also meet “worst case” or those on the tier below “worst case”) a thorough cleaning should be conducted prior to any sampling. If post-sampling confirms that contaminants are below levels of health concern, then as other residential areas are cleaned, post-cleaning sampling should occur periodically as a quality assurance check of cleaning effectiveness.
It should be noted that contaminant/materials of concern may vary as the distance of the residence increases from the WTC. Therefore, an effective cleaning regime at one location may need to be modified for anther location.
If results in worst-case locations show outdoor contamination/materials present at levels of concern, efForts should be made to reduce these levels and take steps that eliminate transporting them indoors (e g,, reduce contaminant track in by removing or changing shoes prior to entering residence, use HEPA filters on HVAC systems, inspect/change HVAC filters frequently).
VI. Sampling Approach;
1. Interior Air and dust sampling should focus on common/high traffic areas of the building (e.g., lobbies, front entryways) and in a selected number of apartment units where visible dust is and is not reported. These first 2 areas should also be representative of worst case conditions for contaminant/material track-in from outdoors and of fallout deposition. Selecting apartments in
Page 5 of 10
CITY_21MC100_004067230
NYC-WTC_000320054
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000317962
Lab evaluation of residential dust near WTC for asbestos and related contaminants (draft).
14 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000250593
DOH evaluation document for health assessment in WTC-affected area.
13 shared non-person entities · 1 shared topics · similarity 0.992
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000250536
ATSDR/DHAC draft on ambient dust evaluations around WTC areas.
14 shared non-person entities · 1 shared topics · similarity 0.992
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000241970
Draft protocol addressing settled surface dust and airborne materials post-WTC collapse.
14 shared non-person entities · 1 shared topics · similarity 0.990
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000250606
DOH page showing page 1 of sampling protocol for WTC residential areas.
12 shared non-person entities · 1 shared topics · similarity 0.989
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000302176
Residential impact and WTC area dust sampling discussion in ATSDR/DHAC draft, Oct 2001.
14 shared non-person entities · 1 shared topics · similarity 0.994
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000304431
Draft ATSDR/DHAC update on ambient environmental monitoring near WTC; area restrictions noted.
14 shared non-person entities · 1 shared topics · similarity 0.994
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000164417
Chain of custody records and emails forwarding the ATSDR residential and commercial interior sampling program draft.
13 shared non-person entities · 1 shared topics · similarity 0.990
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000152790
Plan for ATSDR indoor air sampling; revised plan noted.
14 shared non-person entities · 1 shared topics · similarity 0.990
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000152814
Draft document outlining concepts and priorities for sampling buildings near the WTC to identify worst-case contamination scenarios.
14 shared non-person entities · 1 shared topics · similarity 0.990
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000152801
Correspondence forwarding a revised indoor air sampling plan focusing on residential areas and concentric zones.
14 shared non-person entities · 1 shared topics · similarity 0.990
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000153247
Draft protocol for assessing airborne and settled dust exposures in residential areas following the World Trade Center collapse.
13 shared non-person entities · 1 shared topics · similarity 0.989
machine-extracted · confidence unavailable · Check page ↗Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000304431
Draft ATSDR/DHAC update on ambient environmental monitoring near WTC; area restrictions noted.
Similarity score 1.000 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000302176
Residential impact and WTC area dust sampling discussion in ATSDR/DHAC draft, Oct 2001.
Similarity score 1.000 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000317962
Lab evaluation of residential dust near WTC for asbestos and related contaminants (draft).
Similarity score 1.000 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000250593
DOH evaluation document for health assessment in WTC-affected area.
Similarity score 0.985 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000152788
A corrupted or unreadable document file containing garbled text and binary data.
Similarity score 0.977 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000153241
Draft protocol for assessing airborne and settled dust exposures in residential areas following the World Trade Center collapse.
Similarity score 0.977 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000317962
Lab evaluation of residential dust near WTC for asbestos and related contaminants (draft).
Similar indexed content
NYC-WTC_000302176
Residential impact and WTC area dust sampling discussion in ATSDR/DHAC draft, Oct 2001.
Similar indexed content
NYC-WTC_000304431
Draft ATSDR/DHAC update on ambient environmental monitoring near WTC; area restrictions noted.
Similar indexed content
NYC-WTC_000250593
DOH evaluation document for health assessment in WTC-affected area.
Similar indexed content
NYC-WTC_000250536
ATSDR/DHAC draft on ambient dust evaluations around WTC areas.
Similar indexed content