NYC-WTC_000338502
Draft AHERA-based guidance on TEM/PCM asbestos analysis and clearance criteria.
6 shared non-person entities · 1 shared topics · similarity 0.970
machine-extracted · confidence unavailable · Check page ↗Draft guidance comparing TEM and PCM microscopy for asbestos identification.
NYC-WTC_000320047–000320049OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
FIRST DRAFT
Testing Methodologies for Asbestos
Air: EPA is currently collecting air samples for asbestos and analyzing them via electron microscopy (TEM). They are using the EPA AHERA TEM guidance (see below)
Transmission Electron Microscopy (TEM)-
• TEM can distinguish between asbestos from non-asbestos material. • TEM can see very thin fibers that are not seen by PCM (see below). • TEM is considered to be the definitive state-of-the-art method for identifying asbestos fibers.
PCM - Phase Contrast Microscopy -
PCM identifies fibers but cannot distinguish asbestos from non-asbestos fibers. Although asbestos fibers less than Sum in length can be identified, only fibers greater than Sum in length are counted. According to ATSDR, CDC, EPA, and NIOSH, fibers less than Sum in length are toxicologically insignificant. Asbestos fibers greater than S um in length, and especially those longer than 10 um, are associated with health effects.
PCM cannot identify fibers with diameters less than 0.25 um. Therefore, in some cases, this method can “underestimate” the number of fibers by missing the thinner fibers. The more sensitive electron microscope (TEM) is required to see these thinner fibers.
• PCM in some cases can also “overestimate” the number of fibers because this method may count non-asbestos fibers.
• Because PCM may overestimate or underestimate asbestos air concentrations, the more definitive TEM method is preferred.
• Many of the early worker and animal exposure studies used the PCM method to determine asbestos exposure levels, and current risk assessment methodologies still use the PCM counting methods. Therefore, the counting rules established by PCM are used for TEM analysis to acquire PCM equivalents (PCMe).
CITY_21MC100_004067223
NYC-WTC_000320047
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000338502
Draft AHERA-based guidance on TEM/PCM asbestos analysis and clearance criteria.
6 shared non-person entities · 1 shared topics · similarity 0.970
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000319796
Fact sheet outlining the 1% asbestos content guideline for cleanup of WTC debris.
7 shared non-person entities · 1 shared topics · similarity 0.959
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000318597
Final draft recommending background asbestos guidance and remediation considerations.
4 shared non-person entities · 1 shared topics · similarity 0.955
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000250730
EPA memo documenting issues with asbestos testing standards post-WTC collapse.
6 shared non-person entities · 1 shared topics · similarity 0.955
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000279331
NYC background to 0.01 PCM/PCMe guidance and related recommendations.
4 shared non-person entities · 1 shared topics · similarity 0.953
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000289635
Final/draft note on follow-up sampling results from ATSDR residential studies.
5 shared non-person entities · 1 shared topics · similarity 0.952
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000321708
Final ATSDR/CDC/EPA/OSHA recommendations and AHERA guidance for WTC-related asbestos exposure.
7 shared non-person entities · 1 shared topics · similarity 0.951
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000140259
Memorandum detailing procedures for asbestos wipe sampling in Lower Manhattan and estimating associated cancer risks from dust exposure.
6 shared non-person entities · 1 shared topics · similarity 0.956
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000151635
EPA memorandum detailing plans for asbestos wipe sampling, projecting airborne dust levels, and estimating increased cancer risks from WTC dust exposure.
6 shared non-person entities · 1 shared topics · similarity 0.956
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000140170
EPA memorandum on wipe sampling methods for asbestos in Lower Manhattan buildings, resuspension projections, and cancer risk estimates from WTC dust exposure.
6 shared non-person entities · 1 shared topics · similarity 0.955
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000302727
Documentation of asbestos fiber analysis method and regulatory limits (PCM/others).
8 shared non-person entities · 1 shared topics · similarity 0.955
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000154652
Internal form used by DEP staff to track comments, actions, and routing for World Trade Center related reports and logs.
6 shared non-person entities · 1 shared topics · similarity 0.952
machine-extracted · confidence unavailable · Check page ↗Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000338505
First-draft explanation of TEM and PCM asbestos identification methods.
Similarity score 1.000 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000279330
First draft outlining TEM/PCM methods for asbestos identification and analysis.
Similarity score 1.000 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000318598
Draft guidance document on TEM/PCM analysis and air testing for asbestos.
Similarity score 0.998 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000250491
Overview of TEM and PCM methods for asbestos identification and levels of concern.
Similarity score 0.991 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000337923
DOH/OSHA letter discussing coordination of asbestos sampling program at WTC site.
Similarity score 0.970 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000437306
Lab report discussing TEM vs optical microscopy and regulatory asbestos limits.
Similarity score 0.969 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000338502
Draft AHERA-based guidance on TEM/PCM asbestos analysis and clearance criteria.
Similar indexed content
NYC-WTC_000319796
Fact sheet outlining the 1% asbestos content guideline for cleanup of WTC debris.
Similar indexed content
NYC-WTC_000140259
Memorandum detailing procedures for asbestos wipe sampling in Lower Manhattan and estimating associated cancer risks from dust exposure.
Similar indexed content
NYC-WTC_000151635
EPA memorandum detailing plans for asbestos wipe sampling, projecting airborne dust levels, and estimating increased cancer risks from WTC dust exposure.
Similar indexed content
NYC-WTC_000140170
EPA memorandum on wipe sampling methods for asbestos in Lower Manhattan buildings, resuspension projections, and cancer risk estimates from WTC dust exposure.
Similar indexed content