NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 24 pages

Bulk asbestos analysis method update, lab manual

Machine-extracted title · confidence 48%

EPA/DOE manual describing identification of asbestos in non-friable bulk materials.

NYC-WTC_000319762–000319785
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

FROM US EPA/OERR (TUE) 1 2. 1 1 ' 01 9:24/ST. 9 : 1 1/NO. 486 1 20 248 3 P 20

ENVIRONMENTAL LABORATORY APPROVAL PROGRAM CERTIFICATION MANUAL

SUBJECT DATE PAGE ITEM NO.

Transmission Electron Microscope Method for 3/1/97 19 of 34 198.4 Identifying and Quantitating Asbestos in Non- Friable Organically Bound Bulk Samples

storage of records for at least three years. Records, whether they be hardcopy or computer files, must be easily accessible and must include: 8.1.5.1. Sample Accessioning. Each sample must pass through an accessioning process that documents; 8.1.5.1.1. Client. This should include name, address, phone number and name of contact person. 8.1.5.1.2. Client Sample Identification. This should include the identification characteristics provided by the client, e.g., identification number, collection site, etc. 8.1.5.1.3. Laboratory Sample Identification. A unique laboratory sample identification number must be assigned to each sample. 8.1.5.1.4. Date of Receipt 8.1.5.1.5. Chain of Custody

8,1.5.1.6. Condition of Sample (Accept/Reiect) 8.1.5.1.7. Type of Sample. This should place the sample In one of several bulk sample categories, e.g., friable, floor tile, etc. 8.1.5.2. Analytical Quality Control. All results of analytical quality control activities must be recorded in an orderly fashion. 8.1.5.3. Equipment and Supply Records. Records must be kept for maintenance, calibration, replacement and repair of pertinent equipment and supplies. For major pieces of equipment (microscopes, hoods, muffle furnaces, carbon evaporators, analytical balances) these records must include manufacturer, model and serial numbers, major components. calibration and maintenance/service information and location of manuals.

CITY_21MC100_003050115

NYC-\/VTC_000319780

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000319780Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000342629

Summary of bulk and TEM sampling with lab analysis and quality control.

Similar indexed content

Compare copies and versions →