Bulk asbestos analysis method update, lab manual

Machine-extracted title · confidence 48%

EPA/DOE manual describing identification of asbestos in non-friable bulk materials.

NYC-WTC_000319762–000319785
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document (TUE) 12. 11- 01 9:22/ST.' 9 •. 1 1ZNO. 486 1 2C248 3 P 18 FROM US EPA/OERR

ENVIRONMENTAL LABORATORY APPROVAL PROGRAM CERTIFICATION MANUAL

SUBJECT DATE PAGE !TEM NO.

Transmission Electron Microscope Method for 3/1/97 17 of 34 198.4 Identifying and Quantitating Asbestos in Non- Friable Organically Bound Bulk Samples

laboratory, the TEM laboratory report should report as verifiable only the percentage of asbestos in that residue. TPrecision and-Accurac^ 7,1. Precision. Based on limited interlaboratory studies conducted by the New York State Department of Health, quantitative TEM yielded relative standard deviations (RSD) of approximately 45% for samples containing between 15 and 30% chrysotile. Most of the variability was traced to the acid-dissolution/filtration step where RSDs were approximately 25% for 50% carbonate compositions. Agreement during TEM quantitation was better, with about 10% RSDs at 85% chrysotile residues. Chatfield (personal communication) has shown intralaboratory results for a variety of VATs where RSDs were less than 5% for chrysotile concentrations between 10 and 20%. 7,2. Accuracy. The accuracy of this method is not completely known at this time. In the same Interlaboratory study, gravimetric tracking of the total inorganic residues yielded a mean standard deviation of 6.6% around a mean of 19% for 4 floor tiles. The final analytical step, estimation of asbestos in the inorganic residue, could be complicated by large amounts of non-asbestos that would interfere with detection or by a few large dense particles that might be preferentially rejected during pipetting. 8. Quality Assurance 8.1. Quality-Assurance Manual. The laboratory's QA manual can be devoted to asbestos analysis or it can be a larger manual comprising many types of analyses. In either case, the QA manual must include at least the following: 8.1.1. Quality Assurance Responsibility. A single individual must be designated

’CITY_21MC100_003050113

NYC-WTC_000319778

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000319778Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000342629

Summary of bulk and TEM sampling with lab analysis and quality control.

Similar indexed content

Compare copies and versions →