NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 24 pages

Bulk asbestos analysis method update, lab manual

Machine-extracted title · confidence 48%

EPA/DOE manual describing identification of asbestos in non-friable bulk materials.

NYC-WTC_000319762–000319785
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document (TUE) 12. 11' 01 9:22/ST. 9 : 1 1/NO. 486 1 20 248 3 P 17 FROM US EPA/OERR

ENVIRONMENTAL LABORATORY APPROVAL PROGRAM CERTIFICATION MANUAL

gOBJlECT DATE PAGE MO.

Transmission Electron Microscope Method for 3/1/97 16 of 34 198.4 Identifying and Quantitating Asbestos in Non- Friable Organically Bound Bulk Samples

client or collector (field identification number, location - Section 8.1.5.1.2)) for each sample. ”6?3. Anaivticar Results. The following information must be reported for each sample; 6.3.1. Color of sample. 6.3.2. Presence or absence of asbestos, total percentage of asbestos, type(s) of asbestos present, and percentage of each asbestos type. Asbestos quantities must be reported as one of the following: 6.3.2.1. "No asbestos detected" - for samples that contained no asbestos. 6.3.2.2 "Trace (fill in tvpe(s)) asbestos detected at less than 1%" - for samples that contained less than 1% asbestos. 6.3.2.3. " (fill in type) asbestos detected at%" - for each type of asbestos type detected at concentrations equal to or greater than 1 %. 6.3.2.4. "% Total Asbestos" - sum from all types reported in Section 6.3.2.3. Percentage should be rounded off to two digits. 6.3.3, Type(s) and estimated percentage(s) of other fibrous materials present 6.3.4. Percentage of nonfibrous matrix material. 6.4. Homogeneity. For samples with obvious layers, the summary must include results as specified in Section 6.3 for each layer. Compositing of layers into a single result is no longer allowed, except for joint compounds in certain cases (U.S.E.P.A. 1994b). 6.5. Disclaimer. The TEM laboratory must report as verifiable only those operations and analyses performed in-lab. For example, if a filter with residue (Section 4.2.3 of ELAP Item 198.1) was received from an outside, PLM-only

CITY_21MC1OO_OO3O5O112

NYC-\/VTC_000319777

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000319777Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000342629

Summary of bulk and TEM sampling with lab analysis and quality control.

Similar indexed content

Compare copies and versions →