NYC 9/11 Public Portal Document
•a
APPENDIX D
Assessing Exposures to Indoor Air and to Residues on Indoor Surfaces
Introduction
The purpose of this Appendix is to provide further details on how procedures were selected to
estimate exposure to indoor air and to residues on indoor surfaces in residences impacted by the
WTC attack.
Indoor Air
Deriving clearance criteria for air samples was completed by using methods described in EPA’s
“Risk Assessment Guidance for Superfund” [RAGS, 1989]. These methods were developed to
assess the risk from contaminants at Superfimd sites. The clearance criteria were calculated
using the formula below:
Clearance criteria = (TR x AT) / (ED xEFx lUR)
where:
TR = Target Risk EF = Exposure Frequency
AT = Averaging Time - Carcinogens lUjR. = Inhalation Unit Risk
ED = Exposure Duration
Target Risk
The target risk identified for these calculations was 1 x 10-4. Appendix C explains the rationale
for this value.
Averaging Time - Carcinogens
For non-carcinogens, AT is the exposure duration expressed in days. For carcinogens, exposure
is averaged over a 70-year lifetime (the factor on which the cancer slope factors are based), and
the AT is 70 years, in days (25,550).
Exposure Duration
A value of 30 years is assumed to match upper bound estimate of time in a residence (EPA,
1997b).
Exposure Frequency
A value of 365 days/year is used to represent a full time resident.
Inhalation Unit Risk
The upper-bound excess lifetime cancer risk estimated to result from continuous exposure to an
agent at a concentration of 1 pg/m^ in air. The interpretation of unit risk would be as follows: if
unit risk = 1.5 x 10‘® pg/m\ 1.5 excess tumors are expected to develop per 1,000,000 people if
exposed daily for a lifetime to 1 pg of the chemical in 1 cubic meter of air. The inhalation unit
risk values used in the calculations are 2.3 E-01 for asbestos (IRIS, 2002), 2.86 E.+05 for dioxin
(Dioxin Reassessrnent, EPA, 2001), and 7.3 E+0 for PAHs (IRIS, 2002).
CITY_21MC100_002452193
NYC-WTC_000319006
OCR can misread numbers and units. Confirm readings against the page image before using them.