I APPENDIX D Assessing Exposures to Indoor Air and to Residues on Indoor Surfaces

Introduction

The purpose of this Appendix is to provide further details on how procedures were selected to estimate exposure to indoor air and to residues on indoor surfaces in residences impacted by the WTC attack.

I Indoor Air Deriving clearance criteria for air samples was completed by using methods described in EPA’s

I “Risk Assessment Guidance for Superfund” [RAGS, 1989]. These methods were developed to assess the risk from contaminants at Superfund sites. The clearance criteria were calculated using the formula below:

Clearance criteria = (TR x AT) / (ED x EFxIUR)

I where:

TR = Target Risk EF = Exposure Frequency

I AT = Averaging Time - Carcinogens ED = Exposure Duration lUR = Inhalation Unit Risk

I Target Risk The target risk identified for these calculations was 1 x 10-4. Appendix C explains the rationale for this value.

I Averaging Time - Carcinogens For non-carcinogens, AT is the exposure duration expressed in days. For carcinogens, exposure

I is averaged over a 70-year lifetime (the factor on which the cancer slope factors are based), and the AT is 70 years, in days (25,550).

I Exposure Duration A value of 30 years is assumed to match upper bound estimate of time in a residence (EPA, 1997b).

I Exposure Frequency A value of 365 days/year is used to represent a full time resident.

I Inhalation Unit Risk The upper-boimd excess lifetime cancer risk estimated to result from continuous exposure to an agent at a concentration of 1 pg/m’ in air. The interpretation of unit risk would be as follows: if unit risk = 1.5 x 10’^ pg/m^, 1.5 excess tumors are expected to develop per 1,000,000 people if exposed daily for a lifetime to 1 pg of the chemical in 1 cubic meter of air. The inhalation unit

I risk values used in the calculations are 2.3 E-01 for asbestos (IRIS, 2002), 2.86 E +05 for dioxin

I

CITY_21MC1OO_OO6741O26

NYC-WTC_000320017

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000320017Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000348649

COPC committee report on World Trade Center contaminants with multi-agency authors.

Similar indexed content

NYC-WTC_000348699

COPC committee report with contributors from EPA, NYC DEP, and state agencies.

Similar indexed content

Compare copies and versions →