15S241 Federal Register / Vol. 52, No. 63 / Thursday, April 30, 1987 / Proposed Rules

s' (NIBS’) "Model Guide Specifications, suspected materials contain asbestos. reassessment information in the Asbestos Abatement in Buildings,’’ July The inspector must then develop an management plan. 18,1986, is associated with precise inventory of areas where samples are Proposed § 763.85(c) states that engineering specifications, found in taken or material is assumed to contain thermal system insulation that has Section 09251 and elsewhere in the asbestos. Finally, the accredited retained its structural integrity and that NIBS’ Model Guide, to construct inspector is required to assess the has an undamaged protective jacket or enclosures sufficiently to control fibers. physical condition of friable known or wrap is deemed non-friable. ii Also, this term, from the standpoint of assumed ACBM as required under £. Sampling and Analysis permanence, is not intended to apply to proposed § 763.88. mini-enclosures described in the EPA 2. Exclusions. 1. Sampling. worker protection rule or Appendix B of the proposed regulation, as these Proposed § 763.99 defines conditions Proposed § 783.86 would permit an enclosures are used temporarily for that would exclude an LEA from all or LEA to assume that suspected ACBM is repair or abatement activities. part of the initial inspection. The ACM. If the LEA does not assume “Functional space” is a term of art accredited inspector is a key element in suspected ACBM to be ACM, the LEA used by the accredited expert to the exclusion process. For all inspection shall use an accredited inspector to appropriately characterize an area as exclusions, areas previously identified collect bulk samples for analysis. containing "significantly damaged as having friable ACM or non-friable EPA expects that a school is likely to friable surfacing ACM” or “significantly ACM that has become friable vvould sample only'friable suspected ACBM. damaged friable miscellaneous ACM.’’ have to be assessed as required under For non-friable suspected ACBM, EPA The "functional space” may be a room, proposed § 763.88. All information anticipates most schools will assume group of rooms, or a homogeneous area, regarding inspection exclusions shall be this material contains asbestos. as determined appropriate by the placed in the management plan. Howeyer, this proposed rule does not accredited expert. Note that the Five types of exclusions for LEAs are preclude a school from sampling.all of functional space includes the area discussed in the proposed rule. First, its suspected ACBM, both friable and above a dropped ceiling. . LEAs do not need to have an initial nonfriable. Sampling of friable surfacing inspection conducted in specific areas of materials should follow the guidance ! ' C. LEA General /lesponsibilities a school where ACBM has already been provided in the EPA publication ' The proposed rule requires LEAs to \ identified. Second, if previous sampling “Simplified Sampling Scheme for Friable designate a person to carry out certain of a specific area of the school indicated Surfacing Materials” (EPA 560/5-85- duties and ensure that such person that no ACM was present, and the 030a). To determine whether an area of receives training adequate to perform sampling was done in substantial surfacing material contains asbestos, the duties. • compliance with the proposed rule, the sufficient samples shall be taken in a ■ Proposed § 763.83 requires LEAs to LEA does not have to perform an initial statistically random manner to provide • i ensure that; (1) Inspections, inspection of that area. Third, LEAs do data representative of each ' reinspections, periodic surveillance and not have to inspect specific areas of homogeneous area being sampled. response action activities are carried out schools where records indicate that all In most cases, sampling of thermal in accordance with the proposed rule; ACM was removed. Fourth, LEAs can receive an inspection exclusion'for system insulation would require an (2) custodial and maintenance accredited inspector to take at least employees are pjoperly trained as schools built after October 12,1988 (the date when management plans are to be three randomly distributed samples per required by this proposed rule; (3) homogeneous area. The proposed rule workers and building occupants are submitted to Governors), if no ACBM was specified for use in the school. Fifth, includes three exceptions to this . informed annually about inspections. proposed requirement for sampling of response actions, and post-response States that receive a waiver from the inspection requirements of the rule can thermal system insulation. First, an ' action activities including reinspections accredited inspector can determine and periodic surveillance: (4) short-term grant exclusions to schools that.had performed inspections in substantial through visual inspection that the workers (e.g., telephone repair workers) material is non-ACM (e.g:, fiberglass). who may come in contact with asbestos compliance with the rule. Second, only one sample is required for in a school are provided information 3. Reinspections. patched homogeneous areas of thermal about locations of asbestos-containing Proposed § 783.85(6) would require system insulation. Third, an accredited building material (ACBM) and are LEAs to have accredited inspectors inspector needs to collect an appropriate instructed in safe work practices; (5) conduct reinspections at least once number of samples to determine warning labels are posted as required every 3 years. The inspector must whether cement tees are ACM. by this proposed rule; and (8) reinspect all known or assumed ACBM For friable miscellaneous material or management plans are available for / .'f review and that parent, teacher, and and shall determine by touching non-friable suspected ACBM, an whether non-friable material has accredited inspector must collect bulk 'I employee organizations are notified of become friable since the last inspection. samples in an appropriate manner. the availability of the plan. The inspector may sample any newly 2. Analysis. D. Inspections and Reinspections friable materials or continue to assume the material to be ACM. The inspector ' Proposed § 763.87 requires analysis of 1.Inspections. shall record changes in the material’s . bulk samples by laboratories accredited it Proposed $ 763.85 would require LEAs conditions, sample locations, and the by NBS. In the period before NBS has to have an accredited inspector visually inspection date for inclusion in the developed its accreditation program, I inspect all areas of each school building management plan. In addition, the laboratories which have received i .i to identify locations of all friable and nonfriable suspected ACBM, determine friability by touching, and either sample inspector must assess newly friable known or assumed ACBM, re-assess the condition of friable known or assumed interim accreditation from EPA may be used to analyze samples. After receiving the sample results, the LEA must the suspected ACBM or assume that ACBM, and include assessment and . consider an area to contain asbestos if

'I

NYC-WTC_000318760

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000318760Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →