Federal Register / Vol. 52, No. 210 / Friday, October 30, 1987 / Rules and Regulations 41837
things, a suggested format for inspection believed this is a misrepresemtation of determination of a fiber's quantity by and management plans. In addition, EPA the true nature of the material, which is XRD. Additionally, vr'tdated methods has developed a model course for , still friable under its covering. for the use of electron .. Ic. iscopy in accreditation of inspectors and The Agency agreed with comments bulk asbestos analysis do .lOt exist at management planners which will that stale friable thermal system this time. New developments in electron provide uniforrri guidance to inspectors insulation cannot properly be “deemed" microscopy or XRD technology may lead and management planners regarding nonfriable. This constitutes an EPA to reconsider the use of these tools their responsibilities. Further, before any inaccurate depiction of the true nature for primary analysis at a future time. course is offered to accredit inspectors of this material. An undamaged jacket A number of comments sought and management planners, it must be on thermal system insulation may be clarification on the laboratory reviewed and approved by EPA in properly seen as an enclosure, which accreditation program. Two laboratory accordance with the provisions of the prevents fiber release and reduces accreditation programs are currently Model Accreditation Plan. This review hazard, but does not change the being developed by the NBS for proc&ss will help ensure that inspectors characteristics of material friability laboratories which analyze bulk and air and management planners receive behind or under the eiyclosure. samples for asbestos. The bulk uniform guidance. However, while the Agency considers accreditation program .is expected to be The Agency received comments about it inappropriate to "deem" or operational in early FY89. The air the requirement for reinspection every 3 characterize friable thermal system accreditation program is expected to be years by an accredited inspector. Some insulation as nonfriable, it is appropriate complete in late FY89. commenters supported this requirement, to "treat" this material as nonfriable. Until the NBS bulk accreditation others thought the reinspection should EPA. in its guidance and technical program is complete, EPA will establish be more frequent, still others felt that assistance activities, has traditionally an interim accreditation program for the reinspection should be less frequent treated undamaged friable thermal laboratories which analyze bulk system insulation as nonfriable. for the and that use of an accredited inspector samples by PLM. EPA will provide purposes of cleaning and other O&M was unnecessary. EPA believes a 3-year interim accreditation to laboratories activities. reinspection requirement to be which correctly identify four samples as Accordingly, the regulation at conducted by an accredited inspector is either asbestos-containing or § 763.85(c) has been modified to state nece,ssary. The Agency is concerned ncnasbestos-containing. EPA announced that thermal system insulation that has that an annual reihspection as suggested the availability of this program in the retained its structural integrity and that by some commenters would prove Federal Register of September 3.1987 has an.undamaged protective jacket or unduly burdensome to LEAs while (52 FR 33470). The deadline for wrap that prevents fiber release shall be providing limited information. The rule laboratory participation in the first treated as nonfriable. provides for periodic surveillance Ultimately, however, the change in round was September 30,1987. A formal activities at least twice a year to keep wording does not change the intent of listing of the first round of accredited track of changes in the ACBM's the regulation that thermal insulation labs will be available in January 1988. condition. On the other hand, the that has both an intact protective jacket Individual laboratories will be informed Agency believes a reinspection every 5 and has retained structural integrity of their performance by letter in years is too long a period of time for a should be subject to periodic December 1987. Laboratories which did school's ACBM not to be checked bj' an surveillance and preventive measures. not participate in the first round of accredited inspector. ACBM could and that custodial and maintenance accreditation will be considered in the deteriorate substantially over a 5-year workers must be trained to deal with second round of accreditation, which is period of time. The Agency disagrees such material. Furthermore, if the scheduled for April 1988. with comments suggesting that thermal insulation is disturbed or is X Assessment unaccredited persons should be about to be disturbed such that it would permitted to perform reinspections. be rendered friable, all applicable O&M One comment regarding assessment of Accredited inspectors will have special and response action provisions will the physical condition of the material by training to determine changes in the apply. EPA believes that this is accredited inspectors was that EPA physical condition of ACBM. The consistent with NESHAP. which should require accredited inspectors to purpose of periodic surveillance, which considers such material to be friable give reasons for their assessment may be conducted by unaccredited when disturbed or removed. conclusions. EPA agrees with the personnel, is to note observable changes comment. This requirement would in the condition of ACBM. For example. E. Bu/k Asbestos Sample Measurement provide reviewers of management plans a periodic surveillance check would Comments suggested that EPA allow at the State level with additional, useful notice a water leak through an ACBM use of electron microscopy and X-ray information in judging whether the ceiling. The Agency believes the diffraction (XRD) for the analysis of management plan accurately reflects the combination of the semiannual periodic bulk samples. condition of the school building. The ' surveillance check and the 3-year For purposes of tin's rule. PLM will be Agency believes the increase in the reinspection by an accredited inspector used for analyzing bulk samples for recordkeeping burden is small. As a provides for adequate scrutiny of ACB.M asbestos. The analytical method to be result, § 763,86(b) has been changed to present in schools. employed is the EPA "Interim Method require the accredited inspector to give Industry commenters commended the for the Determination of Asbestos in written reasons for the decision to proposed rule for allowing thermal Bulk Insulation Samples" (40 CFR 763, classify ACBM. system insulation "that has retained its Appendix A to Subpart F). EPA feels Some commenters suggested that structural integrity and that has an that the existing EPA PLM protocol is management planners should be undamaged protective jacket or wrap technically sufficient for determining required to use one assessment method that prevents fiber release" to be asbestos fiber identity and quantity. in developing recommendations for "deemed" nonfriable for the purpiises of Currently, allowance is made in the EPA LEAs about response actions, 'fhese this regulation. Others commenters PLM protocol for additional commenters suggested a variety of
NYC-WTC_000318690
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000318755
Background report on asbestos and related contaminants for WTC environment, 1987.
27 shared non-person entities · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000449399
EPA Part 763 asbestos SOP excerpt with subparts and scope.
27 shared non-person entities · similarity 0.994
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000451982
Chain-of-custody and SOP excerpt focusing on asbestos validation and PCB spiking.
27 shared non-person entities · similarity 0.994
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000434918
Continuation of the asbestos validation SOP text with definitions and scope.
27 shared non-person entities · similarity 0.994
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000445234
EPA Part 763 subpart I excerpt regarding asbestos, testing parameters and definitions.
27 shared non-person entities · similarity 0.994
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000452898
Chain-of-custody excerpt referencing Part 763 asbestos procedures and compliance.
27 shared non-person entities · similarity 0.994
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000433711
Page from Part 763 asbestos standard; references to testing and enforcement sections.
27 shared non-person entities · similarity 0.994
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000445985
Chain-of-custody excerpt referencing Part 763 sections and regulatory definitions.
27 shared non-person entities · similarity 0.994
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000435395
Part 763 Subpart text related to asbestos standards and testing definitions.
27 shared non-person entities · similarity 0.994
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000438164
EPA SOP excerpts and references for asbestos validation and inspections.
27 shared non-person entities · similarity 0.994
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000442707
Pallet of Part 763 asbestos-related standard references and definitions.
27 shared non-person entities · similarity 0.994
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000434667
Environmental protection document detailing Part 763 asbestos definitions and related sections.
27 shared non-person entities · similarity 0.994
machine-extracted · confidence unavailable · Check page ↗Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000318755
Background report on asbestos and related contaminants for WTC environment, 1987.
Similarity score 0.969 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000318755
Background report on asbestos and related contaminants for WTC environment, 1987.
Similarity score 0.967 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000362205
SOP validation study references and definitions for asbestos Part 763 sections.
Similarity score 0.966 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000442707
Pallet of Part 763 asbestos-related standard references and definitions.
Similarity score 0.966 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000443893
Chain-of-custody appendix with Part 763 asbestos standards and definitions.
Similarity score 0.966 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000433711
Page from Part 763 asbestos standard; references to testing and enforcement sections.
Similarity score 0.966 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000318755
Background report on asbestos and related contaminants for WTC environment, 1987.
Similar indexed content
NYC-WTC_000449399
EPA Part 763 asbestos SOP excerpt with subparts and scope.
Similar indexed content
NYC-WTC_000451982
Chain-of-custody and SOP excerpt focusing on asbestos validation and PCB spiking.
Similar indexed content
NYC-WTC_000434918
Continuation of the asbestos validation SOP text with definitions and scope.
Similar indexed content
NYC-WTC_000445234
EPA Part 763 subpart I excerpt regarding asbestos, testing parameters and definitions.
Similar indexed content