NYC 9/11 Public Portal Document
OJficf Efutpmtnt Asttflot Micrv-nacuum SampUnj Report January 7, 2003
JOO Chu/vJi S/feet a/uf 40 Warth Street, /fthi York, f4eiv York
THC Project f^utnitr 33052-0000-0001$
2.0 PROCEDURE
Asbestos dust samples were collected using American Society for Testing and Materials (ASTM)
Test Method D57S5-95 for asbestos microvacuum Sampling. The samples were analyzed using
indirect analysis (Filter Sample Analysis) of dust by Transmission Electron Microscopy (TEM)
for asbestos structure number concentration. The analyses was performed by EMSL Analytical,
Inc. which is an independent New York State Department of Health (NYSDOH) and
Environmental Laboratory Approval Program (ELAP) certified laboratory located in Manhattan,
New York. Laboratory data and chain of custody forms are attached in Appendix A of this
report. Results of sampling are presented in Tables 1 and 2. Table 1 presents results for 100
Church Street, Table 2 presents results for 40 Worth Street. Results were compared to the post-
cleaning individual sample target concentration of less than 10.000 asbestos structures.pcr square
centimeter (str/cm’) and a geometric mean concentration of less than 1,000 str/cm’, which were
established as clearance criterion for this project. A total of twenty-five asbestos micro-vacuum
samples were collected from the internal components of representative office equipment
(approximately ten percent).
3.0 RESULTS
Five (5) micro-vacuum samples of fourteen (14) collected from the 20"' floor at 100 Church
Street office on December 12 and 13, 2002 and five (5) samples of eleven (11) collected from
the 4'**' floor at 40 Worth Street Office on December 12, 2002 indicated elevated concentrations
of asbestos in dust.
Results for samples collecTcd inside the equipment at 100 Church Street were detected in the
following concentrations (in str/cm^):
• Copiers less then (<) 1,596 to 118,078
• CPUs <997 to 17,020
• Monitors 1,330 10 1,834,990
• UPS < 1,330
• Server 15,358
• Fax 4,787
machine
• Plotter 29,918
2
CI TY_2 iMcT0020?8959^5
NYC-WTC_000318675