DOHMH asbestos testing fact sheet, 100 Church/40 name, 2002

Machine-extracted title · confidence 25%

Draft fact sheet explaining asbestos testing at 100 Church Street and 40 name Street after 2001 events.

NYC-WTC_000318655–000318657
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document n

^on (str/cm^)

Equipment Co «■ Copiers (6) kt^<^to<U8,0782s CPUs (2) <997 to 17J120~ Monitors (2) l,33^.to^^^9jp UPS Server 15,358

I* o Fax machine Plotter 4,787______ 29,918 Table 2 shows the results for micro-vacuum samples taken from inside equipment V at 40 Worth Street. The-geometr4c mean cnnrentrato^i that lucation-was d+;56t-strBWHi3^

Equipment Concentration (str/cm^) (5 CPUs (3) 7,978 to 136,960 Printers (2) <2,128 to 6,383 Projector______ _______ <1,596_______ Scanner _______ 4287_______ Monitor _______ 136,960 Laptop computer _______ 19,547 Copier________ _______ 5L061_______ Fax machine 2191

2° Standards do not exist for the presence of asbestos in dust collected using the A micro-vacuum method. Guidance values are limited due to a lack of information \ and have generally been applied to accessible surfaces (not the inside of office y equipment). The presence of asbestos fibers in a micro-vacuum samples collected / from an urban environment is not unusual. In one of very few studies done (still trying to obtain more info here), the geometric mean of outdoor dust in urban . ■ environment was 5, lOOstr/cm^. To find dust containing asbestos structures in 5^ electronic equipm'SSt’lTproFably nqj: unusual, although some of the high values \ obtained suggest contamination. I The relationship between the levels found and OixzAm? health effects is unknown'?~~\ k— \ AhSamples______________ S______ V zS^^he results of the airborne asbestos sampling in workplace air indicated that / / I asbestos levels were below the Asbestos Hazard Emergency Response ( K I (AHERA) standard of 70 structures per square millimeter (str/mm^) or 7,000 \ seven samples were all less than 70 str/mm^ (five below detection J Aij two at 13.33 str/mm^). The AHERA standard is used to decide when children I re-enter school buildings following asbestos-removal activities. o The results of personal air samples were within the US and New York City re- occupancy standard for asbestos in community and residential buildings of 0.01 asbestos fibers/cubic centimeter (f/cc) in indoor air. Both samples contained less than 0.002 fee (the detection limit) and no asbestos fibers were present. I will < zzfj also put in the OSHA Std. VY'®" u - . cZ)

CITY_21MC100_008959228

NYC-WTC_000318656

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000318656Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →