NYC 9/11 Public Portal Document

FIRST DRAFT

Testing Methodologies for Asbestos

Air; EPA is currently collecting air samples for asbestos and analyzing them via electron microscopy (TEM). They are using the EPA AHERA TEM guidance (see below)

Transmission Electron Microscopy (TEM)-

o TEM can distinguish between asbestos from non-asbestos material. G TEM can see very thin fibers that are not seen by PCM (see below). O TEM is considered to be the definitive state-of-the-art method for identifying asbestos fibers.

PCM - Phase Contrast Microscopy -

o PCM identifies fibers but cannot distinguish asbestos from non-asbestos fibers. Although asbestos fibers less than Sum in length can be identified, only fibers greater than Sum in length are counted. According to ATSDR, CDC, EPA, and NIOSH, fibers less than Sum in length are toxicologically insignificant. Asbestos fibers greater than S um in length, and especially those longer than 10 um, are associated with health effects.

o PCM cannot identify fibers with diameters less than 0.25 um. Therefore, in some cases, this method can “underestimate” the number of fibers by missing the thinner fibers. The more sensitive electron microscope (TEM) is required to see these thinner fibers.

o PCM in some cases can also “overestimate” the number of fibers because this method may count non-asbestos fibers.

o Because PCM may overestimate or underestimate asbestos air concentrations, the more definitive TEM method is preferred.

o Many of the early worker and animal exposure studies used the PCM method to determine asbestos exposure levels, and current risk assessment methodologies still use the PCM counting methods. Therefore, the counting rules established by PCM are used for TEM analysis to acquire PCM equivalents (PCMe).

CITY_21MC100_008958736

NYC-WTC_000318598

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000318598Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000279330

First draft outlining TEM/PCM methods for asbestos identification and analysis.

Similar indexed content

Compare copies and versions →