NYC-WTC_000317874
GEI covers PPE requirements and preparation for PCB cleanup operations.
4 shared non-person entities · 1 shared topics · similarity 0.917
machine-extracted · confidence unavailable · Check page ↗GEI explains disposal of PCB hazardous waste in drums and bulk tanks with handling.
NYC-WTC_000317877–000317878OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
< GEI 2.22 - Disposal Of PCB Waste From A PCB Spill Site Section 2.00 - Spill Response and Cleanup
IDENTIFICATION
This GEI describes the procedure for disposing of liquid and solid PCB hazardous waste in drums and in bulk from a PCB spill site. Wastes from small spills will be placed into drums, and wastes from large spills will be placed in tank trucks (liquids) and rolloff containers (solids). Wastes generated in the field or at unmanned facilities will be transported to either a nearby service center with a temporary PCB waste storage area, the GhemLabAstoria PCB Storage Facility, or directly to a commercial treatment, storage, and disposal facility (TSDF). Wastes generated at a manned Con Edison facility will be transported to either the GhemL-abAstoria PCB Storage Facility -or a commercial TSDF.
[ PREPARATION
• To select training applicable to job-specific conditions associated with this GEI, refer to Appendix A, Selection of Job-Specific Training Requirements. • Obtain the following equipment as required: - 55-gallon steel drums with lids (C/S No. 025-2692). - Hazardous waste accumulation labels (C/S No. 024-6579). - White PCB labels (Ml mark) (C/S No. 659-2828).
PERSONAL PROTECTIVE EQUIPMENT
• Before beginning work, determine what potential hazards may exist and select the minimum appropriate level of protection necessary. Refer to the Hazard Assessment Flow Diagram presented in Appendix B to select the proper personal protective equipment (PRE) based on potential hazards at the work site.
NOTE: See your supervisor if you are not sure of the selection of proper PPE.
• Additional PPE required for this task may include: - Work Gloves.
SMALL PCB SPILLS
• If a small PCB spill occurs, collect the liquid waste (dielectric fluid, wash water, etc.) and solid waste (used PPE, absorbent pads, soil, small equipment, etc.) in 55-gallon drums. • Leave 3 inches of headspace in liquid and solid waste drums. • Ensure that the following labels and markings appear on each PCB waste drum: - A hazardous waste accumulation label with the type of waste (oil, oil/water, water, or solid) written on the label. - The date that the waste was originally placed in the drum written on the hazardous waste accumulation label. GEI 2.22 - Disposal Of PCB Waste From A PCB Spill Site Revision No.: 1 Section 2.00 - Spill Response and Cleanup Date:_07/22/99 Page 1 of 2 ^>1998 Consolidated Edison Co. of New York, Inc.
CITY_21MC100_003049930
NYC-WTC_000317877
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000317874
GEI covers PPE requirements and preparation for PCB cleanup operations.
4 shared non-person entities · 1 shared topics · similarity 0.917
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000317871
GEI outlines cleanup procedures for PCB-contaminated soil and debris with prep steps.
3 shared non-person entities · 1 shared topics · similarity 0.915
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000317868
GEI describes PCB wipe sampling identification and custody procedures for surfaces.
4 shared non-person entities · similarity 0.887
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000250622
NYC DOH fact sheet describing PCBs in relation to WTC fires and potential indoor exposure.
2 shared non-person entities · similarity 0.845
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000095834
Part IV of a regulatory submission detailing the waste characterization and management plan for 30 West Broadway remediation.
2 shared non-person entities · 1 shared topics · similarity 0.857
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000096519
Cover page for Part IV of a remediation and deconstruction management plan document prepared for the State of New York regarding 30 West Broadway.
2 shared non-person entities · 1 shared topics · similarity 0.856
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000124614
Administrative document identifying the location and BIN for properties at 74-90 Church Street.
2 shared non-person entities · 1 shared topics · similarity 0.850
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000239600
Letter report from ATC Associates detailing wipe sample results for polychlorinated biphenyls (PCBs) collected at PS 131M on August 22, 2002.
2 shared non-person entities · similarity 0.846
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000351129
Wipe sample PCB analysis for P.S. 2, Sept 2002.
2 shared non-person entities · similarity 0.846
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000375664
Results of PCB wipe samples collected at PS 150M in Feb 2002.
2 shared non-person entities · similarity 0.844
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000302191
Summary of chain-of-custody covering 1/12-18/02 (ICS 201), NYC-WTC bag/file identifiers.
1 shared non-person entities · 1 shared topics · similarity 0.844
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000382359
ATC wipe sample report for PCBs at P.S. 234M, March 2002.
2 shared non-person entities · similarity 0.844
machine-extracted · confidence unavailable · Check page ↗Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000317874
GEI covers PPE requirements and preparation for PCB cleanup operations.
Similarity score 0.958 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000317874
GEI covers PPE requirements and preparation for PCB cleanup operations.
Similarity score 0.956 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000317871
GEI outlines cleanup procedures for PCB-contaminated soil and debris with prep steps.
Similarity score 0.955 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000317874
GEI covers PPE requirements and preparation for PCB cleanup operations.
Similarity score 0.952 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000134132
Environmental consultant work plan detailing asbestos abatement and demolition procedures for 133-135 Greenwich Street and 21-23 Thames Street.
Similarity score 0.951 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000317871
GEI outlines cleanup procedures for PCB-contaminated soil and debris with prep steps.
Similarity score 0.950 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000317874
GEI covers PPE requirements and preparation for PCB cleanup operations.
Similar indexed content
NYC-WTC_000317871
GEI outlines cleanup procedures for PCB-contaminated soil and debris with prep steps.
Similar indexed content
NYC-WTC_000317868
GEI describes PCB wipe sampling identification and custody procedures for surfaces.
Similar indexed content
NYC-WTC_000095834
Part IV of a regulatory submission detailing the waste characterization and management plan for 30 West Broadway remediation.
Similar indexed content
NYC-WTC_000096519
Cover page for Part IV of a remediation and deconstruction management plan document prepared for the State of New York regarding 30 West Broadway.
Similar indexed content