GEI 2.18 - Cleanup Of PCB Spills From Solid Surfaces / Section 2.00 - Spill Response and Cleanup

=> Cleanup of releases of dielectric fluid containing 500 ppm or greater PCBs must be initiated within 24 hours (or 48 hours for PCB transformers)-aftef-Feeeipt-of-the cihatytiGalre&ijtts. => If the spill occurs during adverse weather or other emergency conditions, refer to GEI 2.12. => If the spill occurs on soil, gravel, sod, or vegetation, refer to GEI 2.17.

CLEANUP

• If possible, soak up spilled liquid with absorbent pads/pigs or Speedi-Dri. Be careful not to drip liquids from absorbent pads and pigs. • If staining remains, create a moat or dike (for example, with pigs or sandbags) to contain wash water that will be generated. • Ooubte-sScrub, wash, and rinse the affected spill area plus 1 foot of the surrounding buffer (clean) zone. Repeat the process. • Use an industrial-strength detergent such as Slix or Penetone Power cCleaner 155 for porous surfaces (for example, concrete) or nonporous surfaces (for example, metal). • Use a household-type detergent for painted surfaces. • Use car wash-type detergents for contaminated vehicles. => Always scrub, wash, and rinse from the outside of the cleanup area toward the center of the spill. • Pump the wash water into drums or soak up the wash water with absorbents. • Envtfonmenb Health ; - e.afhpled atter eleahhp. Post-cleanup sampling is always required for spills of 500 ppm or greater PCBs and one pound or more of PCBs in 50-499 ppm dielectric fluid. Post-cleanup sampling is generally not required for releases of less than one pound of PCBs in 50-499 ppm dielectric fluid unless required by Environment, Health & Safety (EH&S) or a government agency. If samples are required, EH&S will determine the number and locations of the samples. • If post-cleanup sampling is required, do not remove any barricades until EH&S reports that the USEPA cleanup standards have been achieved. • Refer to the Map of Spill Response and Cleanup to determine which GEI provides the proper instructions for Waste Storage, Transport, and Recording.

GEI 2.18 - Cleanup of PCB Spills from Solid Surfaces Revision No.: 1 Section 2.00 - Spill Response and Cleanup Date: 04/09/99 Page 3 of 3 © 1998 Consolidated Edison Co. of New York, Inc.

CITY_21MC100_003049929

NYC-WTC_000317876

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000317876Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →