NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 3 pages

PCB cleanup GEI procedures, soil and debris

Machine-extracted title · confidence 46%

GEI outlines cleanup procedures for PCB-contaminated soil and debris with prep steps.

NYC-WTC_000317871–000317873
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

\

GEI 2.17 - Cleanup Of PCB Spills From Soil, Gravel, Sod, And Vegetation Section 2.00 - Spill Response and Cleanup

=> If the spill occurs during adverse weather or other emergency conditions, refer to GEI 2.12.

CLEANUP

• Draw a field sketch of the spill area, including boundaries and staging area. Specify area affected and area cleaned, including depths of any excavations. • If a spill involves less than one pound of PCBs in 50-499 ppm 270 gallons of -PG6- eentaminated (50 ppm to 499 ppm) dielectric fluid or less than 270 gallons of dielectric fluid with an unknown concentration has-epiHed, remove all soil, gravel, sod, and vegetation with visible traces of dielectric fluid plus a 1-foot horizontal buffer area in 2- to 3-inch vertical layers until no visible traces remain, then backfill with clean soil. • If a spill involves the-dielectric fluid containings 500 ppm or greater PCBs, tf-one pound or more of PCBs more than 270 gallons of in dielectric fluid containing 50 to 499 ppm PCBs-was released, or if more than 270 gallons or more of dielectric fluid with an unknown PCB concentration-wae-released, then remove material in 2-inch to 3-inch layers until no visible traces remain. A minimum of 10 inches of soil must be removed if the spill area is located within 325 feet of a public area. • Post-cleanup sampling is always required for spills of 500 ppm or greater PCBs and one pound or more of PCBs in 50-499 ppm PCBs dielectric fluid. Post cleanup sampling is generally not required for releases of less than one pound of PCBs in 50-499 ppm PCBs dielectric fluid unless required by Environment. Health and Safety (EH&S) or a government agency. If samples are required, EH&S will determine the number and locations of the samples. • If post-cleanup sampling is required, do not remove barricades and do not backfill any excavation until EH&S reports that the USEPA cleanup standards have been achieved. • Refer to the Map of Spill Response and Cleanup to determine which GEI provides the proper instructions for waste storage, transport, and recording.

GEI 2.17 - Cleanup of PCB Spills from Soil, Gravel. Sod, and Vegetation Revision No.: 1 Section 2.00 - Spill Response and Cleanup Date: 04-/09/99 Page 3 of 3 © 1998 Consolidated Edison Co. of New York, Ino.

CITY_21MC100_0 03049926

NYC-WTC_000317873

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000317873Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →