NYC-WTC_000317874
GEI covers PPE requirements and preparation for PCB cleanup operations.
3 shared non-person entities · 1 shared topics · similarity 0.976
machine-extracted · confidence unavailable · Check page ↗GEI outlines cleanup procedures for PCB-contaminated soil and debris with prep steps.
NYC-WTC_000317871–000317873OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
\
GEI 2.17 - Cleanup Of PCB Spills From Soil, Gravel, Sod, And Vegetation Section 2.00 - Spill Response and Cleanup
=> If the spill occurs during adverse weather or other emergency conditions, refer to GEI 2.12.
CLEANUP
• Draw a field sketch of the spill area, including boundaries and staging area. Specify area affected and area cleaned, including depths of any excavations. • If a spill involves less than one pound of PCBs in 50-499 ppm 270 gallons of -PG6- eentaminated (50 ppm to 499 ppm) dielectric fluid or less than 270 gallons of dielectric fluid with an unknown concentration has-epiHed, remove all soil, gravel, sod, and vegetation with visible traces of dielectric fluid plus a 1-foot horizontal buffer area in 2- to 3-inch vertical layers until no visible traces remain, then backfill with clean soil. • If a spill involves the-dielectric fluid containings 500 ppm or greater PCBs, tf-one pound or more of PCBs more than 270 gallons of in dielectric fluid containing 50 to 499 ppm PCBs-was released, or if more than 270 gallons or more of dielectric fluid with an unknown PCB concentration-wae-released, then remove material in 2-inch to 3-inch layers until no visible traces remain. A minimum of 10 inches of soil must be removed if the spill area is located within 325 feet of a public area. • Post-cleanup sampling is always required for spills of 500 ppm or greater PCBs and one pound or more of PCBs in 50-499 ppm PCBs dielectric fluid. Post cleanup sampling is generally not required for releases of less than one pound of PCBs in 50-499 ppm PCBs dielectric fluid unless required by Environment. Health and Safety (EH&S) or a government agency. If samples are required, EH&S will determine the number and locations of the samples. • If post-cleanup sampling is required, do not remove barricades and do not backfill any excavation until EH&S reports that the USEPA cleanup standards have been achieved. • Refer to the Map of Spill Response and Cleanup to determine which GEI provides the proper instructions for waste storage, transport, and recording.
GEI 2.17 - Cleanup of PCB Spills from Soil, Gravel. Sod, and Vegetation Revision No.: 1 Section 2.00 - Spill Response and Cleanup Date: 04-/09/99 Page 3 of 3 © 1998 Consolidated Edison Co. of New York, Ino.
CITY_21MC100_0 03049926
NYC-WTC_000317873
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000317874
GEI covers PPE requirements and preparation for PCB cleanup operations.
3 shared non-person entities · 1 shared topics · similarity 0.976
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000317877
GEI explains disposal of PCB hazardous waste in drums and bulk tanks with handling.
3 shared non-person entities · 1 shared topics · similarity 0.915
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000317868
GEI describes PCB wipe sampling identification and custody procedures for surfaces.
2 shared non-person entities · similarity 0.913
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000124614
Administrative document identifying the location and BIN for properties at 74-90 Church Street.
2 shared non-person entities · 1 shared topics · similarity 0.879
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000334749
ATC report of PCBs in wipe samples collected Feb 14, 2002 at P.S. 150M.
2 shared non-person entities · similarity 0.873
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000375664
Results of PCB wipe samples collected at PS 150M in Feb 2002.
2 shared non-person entities · similarity 0.872
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000138897
Internal DEP coordination regarding comments on 114 Liberty procedures and preparation of a response.
1 shared topics · similarity 0.872
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000162938
Correspondence regarding monitoring activities and documentation for the asbestos cleanup at 114 Liberty Street in early 2003.
1 shared topics · similarity 0.872
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000155174
Chain of custody documentation for cleanup and monitoring samples at 114 Liberty distributed among project team members.
1 shared topics · similarity 0.872
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000302808
Results from sampling platform near World Trade Center; metals, PCBs, PAHs analyzed.
2 shared non-person entities · similarity 0.871
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000351129
Wipe sample PCB analysis for P.S. 2, Sept 2002.
2 shared non-person entities · similarity 0.871
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000382359
ATC wipe sample report for PCBs at P.S. 234M, March 2002.
2 shared non-person entities · similarity 0.869
machine-extracted · confidence unavailable · Check page ↗Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000317874
GEI covers PPE requirements and preparation for PCB cleanup operations.
Similarity score 0.980 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000317874
GEI covers PPE requirements and preparation for PCB cleanup operations.
Similarity score 0.976 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000317874
GEI covers PPE requirements and preparation for PCB cleanup operations.
Similarity score 0.968 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000317877
GEI explains disposal of PCB hazardous waste in drums and bulk tanks with handling.
Similarity score 0.949 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000317868
GEI describes PCB wipe sampling identification and custody procedures for surfaces.
Similarity score 0.949 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000317868
GEI describes PCB wipe sampling identification and custody procedures for surfaces.
Similarity score 0.942 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000317874
GEI covers PPE requirements and preparation for PCB cleanup operations.
Similar indexed content
NYC-WTC_000317877
GEI explains disposal of PCB hazardous waste in drums and bulk tanks with handling.
Similar indexed content
NYC-WTC_000317868
GEI describes PCB wipe sampling identification and custody procedures for surfaces.
Similar indexed content
NYC-WTC_000124614
Administrative document identifying the location and BIN for properties at 74-90 Church Street.
Similar indexed content
NYC-WTC_000334749
ATC report of PCBs in wipe samples collected Feb 14, 2002 at P.S. 150M.
Similar indexed content